Minimally invasive cardiac output monitoring
Authors:
- Patrick MorganPMPatrick Morgan
- Nawaf Al-SubaieNANawaf Al-Subaie
- Andrew RhodesARAndrew Rhodes
- 1 June 2008
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Critical Care
- Vol. 14 (3) , 322-326
Abstract
The measurement of cardiac output in the critically ill constitutes a vital part in the management of these patients. Minimally invasive techniques are gaining popularity as they allow continuous cardiac output monitoring while avoiding the risks associated with pulmonary artery catheterization. This article focuses on some of the commonly used minimally invasive devices that rely on pulse contour waveform analysis. The current studies in the literature that assess the validity and the clinical applications of calibrated and noncalibrated arterial waveform derived cardiac output devices are discussed. The minimally invasive cardiac output monitoring devices available differ in their methodology and application. Currently there is conflicting evidence as to the accuracy of some of these systems and further investigation into their clinical application is required.Keywords
This publication has 38 references indexed in Scilit:
- Hemodynamic monitoring in shock and implications for managementIntensive Care Medicine, 2007
- Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resectionBritish Journal of Surgery, 2006
- Noninvasive techniques for measurements of cardiac outputCurrent Opinion in Critical Care, 2005
- Equipment review: An appraisal of the LiDCO™plus method of measuring cardiac outputCritical Care, 2004
- Goal-directed Intraoperative Fluid Administration Reduces Length of Hospital Stay after Major SurgeryAnesthesiology, 2002
- Meta-analysis of hemodynamic optimization in high-risk patients*Critical Care Medicine, 2002
- A Comparison of Lithium Dilution Cardiac Output Measurements Made using Central and Antecubital Venous Injection of Lithium ChlorideJournal of Clinical Monitoring and Computing, 1999
- Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen deliveryBMJ, 1999
- Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trialBMJ, 1997
- Prospective Trial of Supranormal Values of Survivors as Therapeutic Goals in High-Risk Surgical PatientsChest, 1988