Q-boosting of metal MEMS resonators via localized anneal-induced tensile stress
Authors:
- 1 July 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 10-15
Abstract
Introduction of tensile stress via localized Joule heating has yielded some of the highest metal MEMS resonator Q's measured to date, as high as 48,919 for a 12-MHz ruthenium micromechanical clamped-clamped beam (`CC-beam'). The high Q's continue into the VHF range, with Q's of 7,202 and 4,904 at 61 and 70 MHz, respectively. These marks are substantially higher than the 6,000 at 10 MHz and 300 at 70 MHz previously measured for polysilicon CC-beams, defying the common belief that metal Q cannot compete with conventional micromachinable materials. The low-temperature ruthenium metal process, with highest temperature of 450°C and paths to an even lower ceiling of 200°C, further allows for MEMS post-processing directly over finished foundry CMOS wafers, thereby offering a promising route towards fully monolithic realization of CMOS-MEMS circuits, such as needed in communication transceivers. This, together with its higher Q, may eventually make ruthenium metal preferable over polysilicon in some applications.Keywords
This publication has 9 references indexed in Scilit:
- A 78-microwatt GSM phase noise-compliant pierce oscillator referenced to a 61-MHz wine-glass disk resonator2013
- A micromechanical resonant charge pump2013
- High quality factor resonance at room temperature with nanostrings under high tensile stressJournal of Applied Physics, 2006
- Polycrystalline silicon-germanium films for integrated microsystemsJournal of Microelectromechanical Systems, 2003
- Frequency trimming and Q-factor enhancement of micromechanical resonators via localized filament annealing2002
- VHF free-free beam high-Q micromechanical resonatorsJournal of Microelectromechanical Systems, 2000
- High-Q HF microelectromechanical filtersIEEE Journal of Solid-State Circuits, 2000
- Stresses in thin film metallizationIEEE Transactions on Components, Packaging, and Manufacturing Technology: Part A, 1997
- Measurement and Interpretation of stress in aluminum-based metallization as a function of thermal historyIEEE Transactions on Electron Devices, 1987