Enhanced Electrochemical Detection of Ketorolac Tromethamine at Polypyrrole Modified Glassy Carbon Electrode
Open Access
- 10 April 2007
- journal article
- Published by Springer Nature in Analytical Sciences
- Vol. 23 (4) , 475-478
Abstract
A glassy carbon electrode modified with a coating of polypyrrole (Ppy) exhibited an attractive performance for the detection and determination of a non-steroidal and non-narcotic analgesic compound, ketorolac tromethamine (KT). Cyclic voltammetry, differential pulse and square wave voltammetry were used in a combined way to identify the electrochemical characteristics and to optimize the conditions for detection. For calibrating and estimating KT, square-wave voltammetry was mainly used. The drug shows a well-defined peak at -1.40 V vs. Ag/AgCl in the acetate buffer (pH 5.5). The existence of Ppy on the surface of the electrode gives higher electrochemical active sites at the electrode for the detection of KT and preconcentrate KT by adsorption. The square-wave stripping voltammetric response depends on the excitation signal and the accumulation time. The calibration curve is linear in the range 1 × 10-11 to 1 × 10-7 M with a detection limit of 1.0 × 10-12 M. Applicability to serum samples was also demonstrated. A detection limit of 1.0 ng ml for serum was observed. Square-wave voltammetry shows superior performance over UV spectroscopy and other techniques.Keywords
This publication has 17 references indexed in Scilit:
- Label-free electrochemical DNA sensor based on functionalised conducting copolymerBiosensors and Bioelectronics, 2005
- Reduction of interference signal of ascorbate and urate in poly(pyrrole)-based ammonia sensors in aqueous solutionsElectrochimica Acta, 2004
- Analysis of ketorolac and its related impurities by capillary electrochromatographyJournal of Chromatography A, 2004
- Sensitive determination of acidic drugs and triclosan in surface and wastewater by ion‐pair reverse‐phase liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2004
- Disposable interference-free glucose biosensor based on an electropolymerised poly(pyrrole) permselective filmAnalytica Chimica Acta, 2000
- Electrochemical studies and square wave adsorptive stripping voltammetry of the antidepressant fluoxetineTalanta, 1999
- Square wave polarographic and voltammetric analysis of selected electroreducible drugsInternational Journal of Pharmaceutics, 1991
- KetorolacDrugs, 1990
- Square-wave adsorptive stripping voltammetry of menadione (vitamin K3)Talanta, 1988
- Detection limits with specified assurance probabilitiesAnalytical Chemistry, 1987