Ex vivo biomechanical stability of 5 cricoid‐suture constructs for equine laryngoplasty
Authors:
- Fabrice RossignolFRFabrice Rossignol
- Amelie VitteAVAmelie Vitte
- 12 May 2017
- journal article
- Published by Wiley in Veterinary Surgery
- Vol. 46 (5) , 705-713
Abstract
Objective: To determine the biomechanical properties of 5 suture constructs in the equine cricoid under cyclic loading and load to failure testing.Study design: Ex vivo study.Samples: Seventy‐five equine cadaver larynges.Methods: Each larynx was implanted with 1 of 5 cricoid‐suture constructs. The standard laryngoplasty, where a suture is passed once through the cricoid, including its caudal edge, was used in 2 constructs: 1 with 5 USP Ethibond (ES) and 1 with 2 mm Fibertape (FS). In the third construct, the 2 mm Fibertape was passed twice through the cricoid including its caudal edge (Double Loop—DL). Constructs 4 and 5 used 2 mm Fibertape in a U‐shaped loop passed through the cricoid but excluding its caudal edge. One construct was supported with a metallic button (MB) on the caudo‐ventral aspect of the cricoid while the other included only the U‐shaped loop (U). Constructs were subjected to cyclic loading and to single cycle to failure. Reduction of the left‐to‐right arytenoid angle quotient (LRQ), suture migration, and load at failure were compared.Results: LRQ reduction after cyclic loading was lower in MB and U than ES constructs. During cyclic loading, suture migration was reduced in MB, U, and DL compared to ES constructs. Mean load at failure was lower in FS and U than in ES constructs.Conclusion: Loss of abduction after equine laryngoplasty may be reduced and pullout forces increased by applying a MB construct in the cricoid cartilage. In vivo testing is required to verify these results.Keywords
Funding Information
- Arthrex Company
- Edouard de Rothschild Foundation
This publication has 32 references indexed in Scilit:
- In VitroMechanical Testing of an Alternate Laryngoplasty System(ALPS) for HorsesVeterinary Surgery, 2012
- In Vitro Effect of Ventriculocordectomy Before Laryngoplasty on Abduction of the Equine Arytenoid CartilageVeterinary Surgery, 2011
- Equine Laryngoplasty Sutures Undergo Increased Loading During Coughing and SwallowingVeterinary Surgery, 2010
- Mechanical Evaluation of the Equine LaryngoplastyVeterinary Surgery, 2010
- In Vitro Biomechanical Evaluation and Comparison of FiberWire, FiberTape, OrthoFiber, and Nylon Leader Line for Potential Use During Extraarticular Stabilization Of Canine Cruciate Deficient StiflesVeterinary Surgery, 2010
- Postoperative Race Performance is Not Correlated with Degree of Surgical Abduction After Laryngoplasty in National Hunt Thoroughbred RacehorsesVeterinary Surgery, 2009
- Racing performance after combined prosthetic laryngoplasty and ipsilateral ventriculocordectomy or partial arytenoidectomy: 135 Thoroughbred racehorses competing at less than 2400 m (1997–2007)Equine Veterinary Journal, 2009
- Biomechanical Comparison of Six Suture Configurations Using a Large Diameter Polyester Prosthesis in the Muscular Process of the Equine Arytenoid CartilageVeterinary Surgery, 2008
- In Vitro Comparison of Two Techniques for Suture Prosthesis Placement in the Muscular Process of the Equine Arytenoid CartilageVeterinary Surgery, 2006
- Long‐term survey of laryngoplasty and ventriculocordectomy in an older, mixed‐breed population of 200 horses. Part 1: Maintenance of surgical arytenoid abduction and complications of surgeryEquine Veterinary Journal, 2003