Bedside Peripheral Ultrasound-Guided Vascular Access in 253 Patients Hospitalized With COVID-19 Pneumonia: A Retrospective Italian Study
Authors:
- Francesco OleariFOFrancesco Oleari
- Chiara CitterioCCChiara Citterio
- Salvatore BontiniSBSalvatore Bontini
- Oriella GrassiOGOriella Grassi
- Corrado GozzoCGCorrado Gozzo
- Jessica PremoliJPJessica Premoli
- Maria Pia MezziMMMaria Pia Mezzi
- Stefano RoscioSRStefano Roscio
- Monica MuroniMMMonica Muroni
- Gabriele CremonaGCGabriele Cremona
- Claudia BiasiniCBClaudia Biasini
- Patrizia MordentiPMPatrizia Mordenti
Open Access
- 15 April 2022
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24157
Abstract
Several studies have recommended the use of vascular access in the treatment of COVID-19 patients. However, little is known about the utility and safety of using a peripheral ultrasound-guided vascular access device (UGVAD) at the bedside of hospitalized COVID-19 patients. To examine this, a retrospective monocenter study was carried out at the oncology-hematology department of Azienda Sanitaria di Piacenza, Italy. We retrospectively analyzed data from three general hospitals in a district in North Italy on the positioning of UGVADs used with hospitalized COVID-19 patients. The positioning of the VAD was performed by a dedicated team using ultrasound guidance. The primary endpoint was the duration of VAD until the patient’s recovery or death. The secondary endpoints were complications of the use of VADs, which included vein thrombosis, infections, device malfunction, and viral contamination of the operators. Between February 21, 2020, and April 30, 2020, 253 consecutive hospitalized patients with COVID-19 pneumonia underwent UGVAD positioning. A midline was inserted in 88.53% of the patients, while peripheral central venous catheters and femoral central catheters were inserted in 9.88% and 1.59% of the patients, respectively. The mean lifespan of the VADs was 10.36±9.96 days (range: 1-73). Primary endpoint: The use of the VAD allowed the planned treatment in 92.88% of the patients; in the remaining 7.12%, the VAD was repositioned. Secondary endpoints: Complications of VAD were registered in 15.02% of the patients (dislocation, 9.49%; infection, 1.98%; thrombosis, 1.58%; occlusion, 1.19%; and malfunction, 0.79%). No contamination of the operators was registered. With the limitation of being a retrospective study, our report suggests that ultrasound-guided positioning of VAD may allow the safe clinical management (drug infusion, hydration, parenteral nutrition, and phlebotomy) of hospitalized COVID-19 patients. The observance of recommended procedures protected all operators from infection.Keywords
This publication has 14 references indexed in Scilit:
- Bedside vascular access procedures for COVID-19 patientsThe Journal of Vascular Access, 2020
- Recommendations for the use of vascular access in the COVID-19 patients: an Italian perspectiveCritical Care, 2020
- A Trial of Lopinavir–Ritonavir in Adults Hospitalized with Severe Covid-19New England Journal of Medicine, 2020
- Vascular access in COVID-19 patients: Smart decisions for maximal safetyThe Journal of Vascular Access, 2020
- Characteristics of and Important Lessons From the Coronavirus Disease 2019 (COVID-19) Outbreak in ChinaJAMA, 2020
- Genomic characterisation and epidemiology of 2019 novel coronavirus: implications for virus origins and receptor bindingThe Lancet, 2020
- Peripherally Inserted Central Catheters—Improving Appropriateness With a Dedicated and Rigorous TeamJAMA Internal Medicine, 2016
- ECG or X-ray as the ‘gold standard’ for establishing PICC-tip location?British Journal of Nursing, 2014
- Ultrasound-guided Central Venous Catheterization for Home Parenteral Nutrition and Hydratation in Advanced Incurable Cancer Patients: Results of A Prospective Observational StudyWorld Journal of Oncology, 2011
- Ultrasound-guided central venous catheterization in cancer patients improves the success rate of cannulation and reduces mechanical complications: A prospective observational study of 1,978 consecutive catheterizationsWorld Journal of Surgical Oncology, 2010