Incidence of Distal Stent Graft Induced New Entry vs. Aortic Remodeling Associated With Frozen Elephant Trunk
Authors:
Open Access
- 10 March 2022
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 875078
Abstract
Background: The introduction of the frozen elephant trunk (FET) technique for total arch replacement (TAR) has revolutionized the field of aortivascular surgery by allowing hybrid repair of complex aortic pathologies in a single step through combining an open surgical approach with an endovascular one. FET has been associated with favorable aortic remodeling, however, its is also associated with development of distal stent graft induced new entry (dSINE) tears postoperatively. The rate of aortic remodeling and the incidence of dSINE have been linked together, in addition, there seems to be a relationship between these two variables and FET insetion length as well as graft size. Aims: The scope of this review is to highlight the rate of aortic remodeling as well the incidence of dSINE associated with different FET devices available commercially. This review also aimed to investigate the relationship between aortic remodeling, dSINE, FET insertion length and FET graft size. Methods: We conducted a comprehensive literature search using multiple electronic databases including PubMed, Ovid, Scopus and Embase in order to collate all research evidence on the above mentioned variables. Results: Thoraflex™ Hybrid Plexus seems to yield optimum aortic remodeling by promoting maximum false thrombosis as well true lumen expansion. Thoraflex Hybrid™ is also associated with the lowest incidence of dSINE post-FET relative to the other FET devices on the market. Aortic remodeling and dSINE do influence each other and are both linked with FET graft length and size. Conclusion: The FET technique for TAR shows excellent aortic remodeling but is associated with a considerable risk of dSINE development. However, Thoraflex™ Hybrid has demonstrated itself to be the superior FET device on the aortic arch prostheses market. Since aortic remodeling, dSINE, FET insertion length and stent graft size are all interconnect, the choice of FET device length and size must be made with great care for optimum results.Keywords
This publication has 51 references indexed in Scilit:
- Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case–control studyVascular, 2016
- Association between Aortic Remodeling and Stent Graft-Induced New Entry in Extensive Residual Type A Dissecting Aortic Aneurysm after Hybrid Arch RepairAnnals of Vascular Surgery, 2016
- Frozen elephant trunk surgery in acute aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Mid-term Outcomes and Aortic Remodelling After Thoracic Endovascular Repair for Acute, Subacute, and Chronic Aortic Dissection: The VIRTUE RegistryEuropean Journal of Vascular and Endovascular Surgery, 2014
- Aortic Remodeling as a Prognostic Factor for Late Aortic Events After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection With Patent False LumenJournal of Endovascular Therapy, 2014
- Total arch repair with open triple-branched stent graft placement for acute type A aortic dissection: Experience with 122 patientsThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Thoracic aortic aneurysm expansion due to late distal stent graft‐induced new entryCatheterization and Cardiovascular Interventions, 2014
- The frozen elephant trunk technique for acute type A aortic dissection: results from 15 years of experience†European Journal of Cardio-Thoracic Surgery, 2014
- Predictors of Outcome after Endovascular Repair for Chronic Type B DissectionEuropean Journal of Vascular and Endovascular Surgery, 2012
- Volumetric analysis of type B aortic dissections treated with thoracic endovascular aortic repairJournal of Vascular Surgery, 2011