Reverse total shoulder arthroplasty using a trabecular metal glenoid base plate
Authors:
- 1 July 2016
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 98-B (7) , 969-975
Abstract
Aim: We present the medium-term clinical results of a reverse total shoulder arthroplasty with a trabecular metal glenoid base plate.Patients and Methods: We reviewed 125 consecutive primary reverse total shoulder arthroplasties (RTSA) implanted in 124 patients for rotator cuff arthropathy. There were 100 women and 24 men in the study group with a mean age of 76 years (58 to 89). The mean follow-up was 32 months (24 to 60). No patient was lost to follow-up.There were statistically significant improvements in the mean range of movement and Oxford Shoulder Score (p < 0.001). Kaplan-Meier survivorship at five years was 96.7% (95% confidence interval 91.5 to 98.7) with aseptic glenoid failure as the end point. Radiologically, 63 shoulders (50.4%) showed no evidence of notching, 51 (40.8%) had grade 1 notching, ten (8.0%) had grade 2 notching and one (0.8%) had grade 4 notching. Radiolucency around the glenoid base plate was found in one patient (0.8%) and around the humeral stem in five (4.0%). In all, three RTSA (2.4%) underwent revision surgery for aseptic mechanical failure of the glenoid within 11 months of surgery due to malseating of the glenosphere.Conclusion: The clinical results of this large independent single unit series are comparable to those from previous series of RTSA reported in the literature. A trabecular metal base plate is safe and effective in the medium-term. Cite this article: Bone Joint J 2016;98-B:969–75.Keywords
This publication has 22 references indexed in Scilit:
- Determination and comparison of the smallest detectable change (SDC) and the minimal important change (MIC) of four-shoulder patient-reported outcome measures (PROMs)Journal of Orthopaedic Surgery and Research, 2013
- Scapular Notching: Recognition and Strategies to Minimize Clinical ImpactClinical Orthopaedics and Related Research, 2011
- Do Less Medialized Reverse Shoulder Prostheses Increase Motion and Reduce Notching?Clinical Orthopaedics and Related Research, 2011
- Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: A systematic reviewJournal of Shoulder and Elbow Surgery, 2011
- The Delta III reverse shoulder replacement for cuff tear arthropathyThe Journal of Bone and Joint Surgery. British volume, 2011
- Risk factors for revision after shoulder arthroplastyActa Orthopaedica, 2009
- Treatment of Painful Pseudoparesis Due to Irreparable Rotator Cuff Dysfunction with the Delta III Reverse-Ball-and-Socket Total Shoulder ProsthesisJournal of Bone and Joint Surgery, 2005
- Grammont reverse prosthesis: Design, rationale, and biomechanicsJournal of Shoulder and Elbow Surgery, 2005
- Initial glenoid component fixation in “reverse” total shoulder arthroplasty: A biomechanical evaluationJournal of Shoulder and Elbow Surgery, 2005
- Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuffThe Journal of Bone and Joint Surgery. British volume, 2004