Preclinical comparative assessment of a dedicated pediatric poly‐L‐lactic‐acid‐based bioresorbable scaffold with a low‐profile bare metal stent
- 15 April 2020
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (4) , 878-888
Abstract
Background Polymer‐based bioresorbable scaffolds (PBBS) have been assessed for coronary revascularization with mixed outcomes. Few studies have targeted pediatric‐specific scaffolds. We sought to assess safety, efficacy, and short‐term performance of a dedicated drug‐free PBBS pediatric scaffold compared to a standard low‐profile bare metal stent (BMS) in central and peripheral arteries of weaned piglets. Methods Forty‐two devices (22 Elixir poly‐L‐lactic‐acid‐based pediatric bioresorbable scaffolds [BRS] [6 × 18 mm] and 20 control BMS Cook Formula 418 [6 × 20 mm]) were implanted in the descending aorta and pulmonary arteries (PAs) of 14 female Yucatan piglets. Quantitative measurements were collected on the day of device deployment and 30 and 90 days postimplantation to compare device patency and integrity. Results The BRS has a comparable safety profile to the BMS in the acute setting. Late lumen loss (LLL) and percent diameter stenosis (%DS) were not significantly different between BRS and BMS in the PA at 30 days. LLL and %DS were greater for BRS versus BMS in the aorta at 30 days postimplantation (LLL difference: 0.96 ± 0.26; %DS difference: 16.15 ± 4.51; p < .05). At 90 days, %DS in the aortic BRS was less, and PA BRS LLL was also less than BMS. Histomorphometric data showed greater intimal proliferation and area stenosis in the BRS at all time points and in all vessels. Conclusions A dedicated PBBS pediatric BRS has a favorable safety profile in the acute/subacute setting and demonstrates characteristics that are consistent with adult BRSs.Keywords
This publication has 22 references indexed in Scilit:
- Bioresorbable ScaffoldCirculation Research, 2017
- Bench and initial preclinical results of a novel 8 mm diameter double opposed helical biodegradable stentCatheterization and Cardiovascular Interventions, 2016
- Identifying Gaps in Technology for Congenital Interventions: Analysis of a Needs Survey from Congenital Interventional CardiologistsPediatric Cardiology, 2016
- First reported use of drug‐eluting bioabsorbable vascular scaffold in congenital heart diseaseCatheterization and Cardiovascular Interventions, 2015
- A novel design biodegradable stent for use in congenital heart disease: Mid-term results in rabbit descending aortaCatheterization and Cardiovascular Interventions, 2014
- A novel biodegradable stent applicable for use in congenital heart disease: Bench testing and feasibility results in a rabbit modelCatheterization and Cardiovascular Interventions, 2013
- Ultra-High-Pressure Balloon Angioplasty for Treatment of Resistant Stenoses Within or Adjacent to Previously Implanted Pulmonary Arterial StentsCirculation: Cardiovascular Interventions, 2009
- Novel growth stent for the permanent treatment of vessel stenosis in growing children: An experimental studyCatheterization and Cardiovascular Interventions, 2004
- Development of a Polymer Endovascular Prosthesis and its Implantation in Porcine ArteriesJournal of Interventional Cardiology, 1992
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992