Signal-to-noise ratio, contrast-to-noise ratio and their trade-offs with resolution in axial-shear strain elastography
Authors:
- Thomas A KrouskopTKThomas A Krouskop
- Jonathan OphirJOJonathan Ophir
- 4 December 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (1) , 13-28
Abstract
In axial-shear strain elastography, the local axial-shear strain resulting from the application of quasi-static axial compression to an inhomogeneous material is imaged. In this paper, we investigated the image quality of the axial-shear strain estimates in terms of the signal-to-noise ratio (SNR(asse)) and contrast-to-noise ratio (CNR(asse)) using simulations and experiments. Specifically, we investigated the influence of the system parameters (beamwidth, transducer element pitch and bandwidth), signal processing parameters (correlation window length and axial window shift) and mechanical parameters (Young's modulus contrast, applied axial strain) on the SNR(asse) and CNR(asse). The results of the study show that the CNR(asse) (SNR(asse)) is maximum for axial-shear strain values in the range of 0.005-0.03. For the inclusion/background modulus contrast range considered in this study (<10), the CNR(asse) (SNR(asse)) is maximum for applied axial compressive strain values in the range of 0.005%-0.03%. This suggests that the RF data acquired during axial elastography can be used to obtain axial-shear strain elastograms, since this range is typically used in axial elastography as well. The CNR(asse) (SNR(asse)) remains almost constant with an increase in the beamwidth while it increases as the pitch increases. As expected, the axial shift had only a weak influence on the CNR(asse) (SNR(asse)) of the axial-shear strain estimates. We observed that the differential estimates of the axial-shear strain involve a trade-off between the CNR(asse) (SNR(asse)) and the spatial resolution only with respect to pitch and not with respect to signal processing parameters. Simulation studies were performed to confirm such an observation. The results demonstrate a trade-off between CNR(asse) and the resolution with respect to pitch.Keywords
This publication has 21 references indexed in Scilit:
- Elastographic image quality vs. tissue motion in vivoUltrasound in Medicine & Biology, 2006
- Parametric study of the contact stresses around spherical and cylindrical inclusionsComputational Materials Science, 2002
- Shear strain estimation and lesion mobility assessment in elastographyUltrasonics, 2000
- A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and poisson’s ratios in tissuesUltrasound in Medicine & Biology, 1998
- Error analysis in acoustic elastography. II. Strain estimation and SNR analysisThe Journal of the Acoustical Society of America, 1997
- The nonstationary strain filter in elastography: Part II. Lateral and elevational decorrelationUltrasound in Medicine & Biology, 1997
- Theoretical bounds on strain estimation in elastographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Echographic image mean gray level changes with tissue dynamics: a system-based model studyIEEE Transactions on Biomedical Engineering, 1995
- Ultrasound tissue displacement imaging with application to breast cancerUltrasound in Medicine & Biology, 1995
- Elastography: A quantitative method for imaging the elasticity of biological tissuesUltrasonic Imaging, 1991