Development of an Ultra Mini-Oxygenator for use in Low-Volume, Buffer-Perfused Preparations
- 1 April 2012
- journal article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 35 (4) , 308-315
Abstract
Introduction: Small animal models are widely used in basic research. However, experimental systems requiring extracorporeal circuits are frequently confronted with limitations related to equipment size. This is particularly true for oxygenators in systems with limited volumes. Thus we aimed to develop and validate an ultra mini-oxygenator for low-volume, buffer-perfused systems. Methods: We have manufactured a series of ultra mini-oxygenators with approximately 175 aligned, microporous, polypropylene hollow fibers contained inside a shell, which is sealed at each of the two extremities to isolate perfusate and gas compartments. With this construction, gas passes through hollow fibers, while perfusate circulates around fibers. Performance of ultra mini-oxygenators (oxygen partial pressure (PO2), gas and perfusate flow, perfusate pressure and temperature drop) were assessed with modified Krebs-Henseleit buffer in an in vitro perfusion circuit and an ex vivo rat heart preparation. Results: Mean priming volume of ultra mini-oxygenators was 1.2±0.5 mL and, on average, 86±6% of fibers were open (n=17). In vitro, effective oxygenation (PO2=400–500 mmHg) was achieved for all flow rates up to 50 mL/min and remained stable for at least 2 hours (n=5). Oxygenation was also effective and stable (PO2=456±40 mmHg) in the isolated heart preparation for at least 60 minutes (“venous” PO2=151±11 mmHg; n=5). Conclusions: We have established a reproducible procedure for fabrication of ultra mini-oxygenators, which provide reliable and stable oxygenation for at least 60–120 min. These oxygenators are especially attractive for pre-clinical protocols using small, rather than large, animals.Keywords
This publication has 19 references indexed in Scilit:
- Retrograde heart perfusion: The Langendorff technique of isolated heart perfusionJournal of Molecular and Cellular Cardiology, 2011
- Temperature Control Using a Heat Exchanger of a Cardioplegic System in Cardiopulmonary Bypass Model for RatsArtificial Organs, 2008
- Validation of a Rat Model of Cardiopulmonary Bypass With a New Miniaturized Hollow Fiber OxygenatorASAIO Journal, 2008
- A novel survival model of cardioplegic arrest and cardiopulmonary bypass in rats: a methodology paperJournal of Cardiothoracic Surgery, 2008
- A rat model of cardiopulmonary bypass with cardioplegic arrest and hemodynamic assessment by conductance catheter techniqueBasic Research in Cardiology, 2007
- Good Recovery after Nontransthoracic Cardiopulmonary Bypass in RatsThe Heart Surgery Forum, 2007
- A Small Scale Oxygenator for Cardiopulmonary Bypass in RatsThe International Journal of Artificial Organs, 2006
- Neurologic outcome after cardiopulmonary bypass with deep hypothermic circulatory arrest in rats: Description of a new modelThe Journal of Thoracic and Cardiovascular Surgery, 2006
- A recovery model of partial cardiopulmonary bypass in the ratPerfusion, 2001
- A new simple temperature-controlled membrane oxygenator for the perfusion of isolated rat liversCellular and Molecular Life Sciences, 1985