Selection of capacitors to regulate voltage of a short-shunt induction generator
Author:
- 9 March 2009
- journal article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 3 (3) , 257-265
Abstract
A self-excited induction generator (SEIG) has poor voltage regulation and that restricts wide applicability of the generator. A simple method of selecting the values of fixed and switched capacitors in a short-shunt SEIG driven by a regulated prime mover to maintain the load voltage within the upper and lower acceptable limits is proposed. The values of the capacitors are selected very carefully to minimise the number of switched capacitors needed to satisfy the above voltage criterion, and that would minimise the cost and complexity of the voltage regulator. This requires evaluating the generator characteristics under constant voltage operation. The equations needed to obtain such characteristics are also derived and solved using a numerical based routine ‘fsolve’ given in MATLAB. The proposed method of selecting the capacitor values is then tested on a three-phase, 1.5 kW induction generator operating in a short-shunt configuration. The simulation results obtained by the proposed method are also compared with the corresponding actual values found through an experimental setup and are observed to be in very good agreement.Keywords
This publication has 11 references indexed in Scilit:
- Three-Phase Self-Excited Induction Generators: An OverviewIEEE Transactions on Energy Conversion, 2005
- Analysis and Design of STATCOM-Based Voltage Regulator for Self-Excited Induction GeneratorsIEEE Transactions on Energy Conversion, 2004
- Terminal Voltage Regulation Characteristics by Static Var Compensator for a Three-Phase Self-Excited Induction GeneratorIEEE Transactions on Industry Applications, 2004
- Bibliography on the application of induction generators in nonconventional energy systemsIEEE Transactions on Energy Conversion, 2003
- Steady-state analysis of an isolated self-excited induction generator driven by regulated and unregulated turbineIEEE Transactions on Energy Conversion, 1999
- Effects of long-shunt and short-shunt connections on voltage variations of a self-excited induction generatorIEEE Transactions on Energy Conversion, 1997
- Self-excited induction generators driven by regulated and unregulated turbinesIEEE Transactions on Energy Conversion, 1996
- Selection of capacitors for the self regulated short shunt self excited induction generatorIEEE Transactions on Energy Conversion, 1995
- Performance characteristics and optimum utilization of a cage machine as capacitance excited induction generatorIEEE Transactions on Energy Conversion, 1990
- Voltage compensation of an induction generator with long-shunt connectionIEEE Transactions on Energy Conversion, 1989