Development a stacking pad design for enhancing the sensitivity of lateral flow immunoassay
Open Access
- 23 November 2018
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-10
Abstract
Lateral flow immunoassays (LFIAs) have wide application in point-of-care testing, particularly in resource-poor settings. To achieve signal amplification in a gold nanoparticle-based lateral flow assay without an additional procedure or the need for complex fabrication, a new and simple method was developed for using a “stacking pad” configuration that adds an additional membrane between the conjugation pad and test pad to the conventional AuNP-based LFIA format. This design helps to accumulate the antibody and antigen on the stacking pad, hence extending the antigen/antibody binding interactions to enhance the test’s detection sensitivity. With the enhanced lateral flow assay, as low as 1 ng/mL of Protein A and 15.5 ng/mL of C-reactive protein can be visualized with the naked eye. We also successfully applied the stacking pad system in the analysis of C-reactive protein in human serum and synovial fluid samples. These results suggest that this stacking pad LFIA can provide sensitive and on-site prognosis for detection in synovial fluid and serum samples in resource-limited settings.Keywords
This publication has 53 references indexed in Scilit:
- Vertical flow immunoassay (VFA) biosensor for a rapid one-step immunoassayLab on a Chip, 2012
- Two-dimensional paper networks: programmable fluidic disconnects for multi-step processes in shaped paperLab on a Chip, 2011
- Enhanced Sensitivity of Lateral Flow Tests Using a Two-Dimensional Paper Network FormatAnalytical Chemistry, 2011
- Point-of-care tests for diagnosing infections in the developing worldClinical Microbiology and Infection, 2010
- Rapid tests for sexually transmitted infections (STIs): the way forwardSexually Transmitted Infections, 2006
- Relation of Soft Plaque and Elevated Preprocedural High-Sensitivity C-Reactive Protein Levels to Incidence of In-Stent Restenosis After Successful Coronary Artery StentingThe American Journal of Cardiology, 2006
- Protein adsorption onto polyester surfaces: Is there a need for surface activation?Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- 2-Stage Reimplantation for Infected Total Knee ReplacementClinical Orthopaedics and Related Research, 1996
- Staphylococcus aureusNew England Journal of Medicine, 1984
- A study of the nucleation and growth processes in the synthesis of colloidal goldDiscussions of the Faraday Society, 1951