Significant differences in the expected versus observed longevity of implantable cardioverter defibrillators (ICDs)
- 14 July 2012
- journal article
- research article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 102 (1) , 43-49
Abstract
Implantable cardioverter defibrillator (ICD) is a life-saving therapy for patients at risk of ventricular arrhythmias. Due to its high cost, its cost-effectiveness is highly dependent on its longevity, which is currently only based upon the manufacturer’s predicted device life span. We sought to assess the ICDs’ longevity and the factors influencing it, and to compare the observed (real life) to the expected (manufacturer’s prediction) life span at a device level. We retrospectively identified all patients who underwent an ICD implantation in a tertiary care medical center. For each device, an expected longevity was assigned based on the manufacturer/model, pacing percentage, and number of shocks per year. We defined device failure if the observed survival was shorter than 80 % of the expected. Only devices with follow-up time that exceeded the expected longevity were included. Of the 275 devices in the cohort, 79 (29 %) failed. Median device longevity was 5 years and varied markedly between manufacturers (4.3, 4.8, 5.1, and 6.3 years for Biotronik, St. Jude Medical, Boston Scientific, and Medtronic, respectively). There were significant differences among the manufacturers in device failure rates: 48, 17, 22, and 14 % for Biotronik, St. Jude Medical, Boston Scientific, and Medtronic, respectively). In multivariate analysis, manufacturer, earlier year of implantation, congestive heart failure and chronic renal failure significantly predicted device failure. In conclusion, there is a significant device failure rate among ICDs, with variability among manufacturers, impacting both patients and the medical economic systems.Keywords
This publication has 14 references indexed in Scilit:
- Implantable cardioverter-defibrillator longevity under clinical circumstances: An analysis according to device type, generation, and manufacturerHeart Rhythm, 2012
- Clinical experience with a novel subcutaneous implantable defibrillator system in a single centerClinical Research in Cardiology, 2011
- ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesHeart Rhythm, 2008
- Causes of redo procedures in patients with an implantable cardioverter-defibrillator--long-term follow-up results.2007
- Multicenter experience with failed and recalled implantable cardioverter-defibrillator pulse generatorsHeart Rhythm, 2006
- The Frequency and Incremental Cost of Major Complications Among Medicare Beneficiaries Receiving Implantable Cardioverter-DefibrillatorsJACC, 2006
- Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated CardiomyopathyNew England Journal of Medicine, 2004
- Variability in Implantable Cardioverter Defibrillator Pulse Generator Longevity Between ManufacturersPacing and Clinical Electrophysiology, 2003
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionThe New England journal of medicine, 2002
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaThe New England journal of medicine, 1996