Effective Nonanatomical Endoscopy Training Produces Clinical Airway Endoscopy Proficiency
Authors:
- Peter D. LarsenPLPeter D. Larsen
- Reny SegalRSReny Segal
- Colin P. MarslandCMColin P. Marsland
- 1 September 2004
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 99 (3) , 938-944
Abstract
We studied the effectiveness of two nonanatomical endoscopic dexterity training models: "Choose the Hole" and Dexter. Effectiveness was assessed in terms of time spent training, subjective rating, performance on an anatomical manikin, and clinical performance on fellow participants who acted as awake subjects. Forty-three anesthesia specialists, trainees, and technicians volunteered. Performances were videotaped, timed, and scored with a Global Rating Scale (GRS) from 1 (very poor) to 5 (clearly superior). The Dexter group spent more time training than the Choose the Hole group (median time [range], 152 min [70-510 min] versus 75 min [17-281 min]; P < 0.01). Subjective ratings were better in the Dexter group. In clinical bronchoscopy, the Dexter group was faster (30.7 s [17.1-43.5 s] versus 36.6 s [22.8-105.1 s]; P = 0.02) and had higher GRS scores (mean [sd]: 3.0 [0.4] versus 2.6 [0.6]; P = 0.04), indicating superior performance. Clinical and manikin performance (GRS scores) were significantly correlated (rho = 0.62; P = 0.0001). Benchmark levels of clinical bronchoscopic performance can be anticipated from bench model performance without a clinical learning curve. Dexter is a more effective model for learning endoscopic dexterity than the Choose the Hole model. Airway topicalization with lidocaine in a dose range consistent with published series (490-980 mg or 7.14-14.77 mg/kg) resulted in a frequent incidence of side effects. No major adverse events occurred.Keywords
This publication has 16 references indexed in Scilit:
- Acquisition and maintenance of endoscopic skills: developing an endoscopic dexterity training system for anesthesiologistsJournal of Clinical Anesthesia, 2002
- Fiberoptic Orotracheal Intubation on Anesthetized PatientsAnesthesiology, 2001
- Assessment of technical skills transfer from the bench training model to the human modelThe American Journal of Surgery, 1999
- Education and training in airway managementBritish Journal of Anaesthesia, 1998
- Learning curves for fibreoptic nasotracheal intubation when using the endoscopic video cameraAnaesthesia, 1997
- Fiberoptic Intubation Using Anesthetized, Paralyzed, Apneic PatientsAnesthesiology, 1996
- Teaching fibreoptic intubation in anaesthetised patientsAnaesthesia, 1994
- Models to Facilitate the Learning of Fiberoptic TechniqueInternational Anesthesiology Clinics, 1994
- Learning fibreoptic intubation: fundamental problemsAnaesthesia, 1992
- LEARNING FIBREOPTIC INTUBATION: USE OF SIMULATORS V . TRADITIONAL TEACHINGBritish Journal of Anaesthesia, 1988