Determining the Reliability of a New Method for Measuring Joint Range of Motion Through a Randomized Controlled Trial
Open Access
- 31 December 2019
- journal article
- research article
- Published by Korean Academy of Rehabilitation Medicine in Annals of Rehabilitation Medicine
- Vol. 43 (6) , 707-719
Abstract
To compare the reliability and validity of the Korean range of motion standard protocol (KRSP) for measuring joint range of motion (ROM) with those of the conventional ROM measurement using a goniometer. We conducted a randomized controlled trial involving 91 healthy elderly individuals. We compared two strategies of measuring joint ROM to evaluate the reliability and validity of each standardized protocol: first, the KRSP based on the Chungnam National University guidelines and second, handheld goniometric measurement. In the first strategy, 3 examiners (1 rehabilitation doctor, 1 physical therapist, and 1 physical therapy student) independently measured joint ROM in 46 randomly selected subjects; in the second strategy, another 3 examiners (1 rehabilitation doctor, 1 physical therapist, and 1 physical therapy student) measured joint ROM in 45 randomly selected subjects. The reliability of each protocol was calculated using intraclass correlation coefficient, ICC(2,1), and root mean square error (RMSE). Both protocols showed good to excellent intra-rater reliability. With goniometer use, the inter-rater reliability was low-ICC(2,1), 95% confidence interval ranged from 0.643 (0.486-0.783) to -0.078 (-0.296-0.494)- and RMSE was high. With the KRSP, the inter-rater reliability ranged from 0.846 (0.686-0.931) to 0.986 (0.972-0.994) and RMSE was low. ROM measurements using the KRSP showed excellent reliability. These results indicate that this protocol can be the reference standard for measuring ROM in clinical settings as an alternative to goniometers.Keywords
Funding Information
- Ministry of Trade, Industry and Energy (R0004840)
This publication has 30 references indexed in Scilit:
- Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscopeBMC Musculoskeletal Disorders, 2013
- Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis – an inter-rater studyBMC Musculoskeletal Disorders, 2012
- Reliability of goniometric measurements in children with cerebral palsy: A comparative analysis of universal goniometer and electronic inclinometer. A pilot studyBMC Musculoskeletal Disorders, 2011
- The reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometerPhysiotherapy Theory and Practice, 2011
- Upper Limb Portable Motion Analysis System Based on Inertial Technology for Neurorehabilitation PurposesSensors, 2010
- Obesity effect on male active joint range of motionErgonomics, 2010
- How reliably do rheumatologists measure shoulder movement?Annals of the Rheumatic Diseases, 2002
- Reliability of goniometric measurements and visual estimates of ankle joint active range of motion obtained in a clinical settingArchives of Physical Medicine and Rehabilitation, 1993
- Axial Rotation Gravity GoniometerClinical Orthopaedics and Related Research, 1990
- The Equivalence of Weighted Kappa and the Intraclass Correlation Coefficient as Measures of ReliabilityEducational and Psychological Measurement, 1973