Propofol Blood Concentration and the Bispectral Index Predict Suppression of Learning During Propofol/Epidural Anesthesia in Volunteers
Authors:
- Kate LeslieKLKate Leslie
- Daniel I. SesslerDSDaniel I. Sessler
- Marc SchroederMSMarc Schroeder
- Kristin WaltersKWKristin Walters
- 1 December 1995
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 81 (6) , 1269-1274
Abstract
Propofol is often used for sedation during regional anesthesia. We tested the hypothesis that propofol blood concentration, the Bispectral Index and the 95% spectral edge frequency predict suppression of learning during propofol/epidural anesthesia in volunteers. In addition, we tested the hypothesis that the Bispectral Index is linearly related to propofol blood concentration. Fourteen healthy, male volunteers were studied on three randomly ordered days: no propofol, target propofol blood concentration 1 microgram/mL, and target propofol blood concentration 2 micrograms/mL. Each day, epidural anesthesia (approximately T11 level) was induced using 2% 2-chloroprocaine. Propofol was infused by a computer-controlled pump, and propofol concentration measured in central venous blood. We administered a Trivial Pursuit-type question task on all 3 days. The electroencephalogram was monitored continuously (Fp1, Fp2; reference, Cz; ground, mastoid). Propofol caused concentration-related impairment of learning. The propofol blood concentration suppressing learning by 50% was 0.66 +/- 0.1 microgram/mL. The Bispectral Index value when learning was suppressed by 50% was 91 +/- 1. In contrast, the 95% spectral edge frequency did not correlate well with learning. The Bispectral Index decreased linearly as propofol blood concentration increased (Bispectral Index = -7.4.[propofol] + 90; r2 = 0.47, n = 278). There was no significant correlation between the 95% spectral edge frequency and propofol concentration. In order to suppress learning, propofol blood concentrations reported to produce amnesia may be targeted. Alternatively, the Bispectral Index may be used to predict anesthetic effect during propofol sedation.Keywords
This publication has 25 references indexed in Scilit:
- Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide AnesthesiaAnesthesiology, 1994
- Propofol Causes a Dose-dependent Decrease in the Thermoregulatory Threshold for Vasoconstriction but Has Little Effect on SweatingAnesthesiology, 1994
- Does Nitrous Oxide Antagonize Isoflurane-induced Suppression of Learning?Anesthesiology, 1993
- The Effects of Preinduction Warming on Temperature and Blood Pressure during Propofol/Nitrous Oxide AnesthesiaAnesthesiology, 1993
- Effective concentration 50 for propofol with and without 67% nitrous oxideActa Anaesthesiologica Scandinavica, 1993
- Thiopental Pharmacodynamics II. Quantitation of Clinical and Electroencephalographic Depth of AnesthesiaAnesthesiology, 1992
- Thiopental Pharmacodynamics I. Defining the Pseudo–Steady-state Serum Concentration–EEG Effect RelationshipAnesthesiology, 1992
- No Evidence of Classical Conditioning of Electrodermal Responses during AnesthesiaAnesthesiology, 1992
- PropofolAnesthesiology, 1989
- Plasma Drug Efflux-A New Approach to Optimization of Drug Infusion for Constant Blood Concentration of Thiopental and MethohexitalAnesthesiology, 1987