Abstract
Due to the potential for high power density and high efficiency, the high-frequency link matrix converter has been increasingly used in power conversion. However, there is a large voltage difference on the leakage inductance of the high frequency transformer, resulting in high current stress. High current stress will reduce hardware utilization, increase costs, and reduce efficiency. To optimize the operation of the high-frequency link matrix converter, the control method of H-bridge duty cycle variable by adjusting the modulation index and phase shift angle is proposed in this article to keep converter in the lowest current stress state. Then, to obtain the combination of phase shift angle and modulation index at different powers, a mathematical model of the transferred power is established based on the sector division of space vector modulation. Experimental results on a high-frequency link matrix converter are provided to verify the effectiveness of the proposed method.
Funding Information
  • National Natural Science Foundation of China (52377199, 52277202)