Root Canal Cleaning after Different Irrigation Techniques: An Ex Vivo Analysis
Open Access
Abstract
Background and Objectives: The endodontic space is a complex area on both micro and macro levels; therefore, traditional irrigation techniques may not guarantee a complete cleaning of such a complicated tridimensional system. The presented ex vivo study aimed to evaluate root canal cleanliness, obtained through an equal volume of traditionally applied sodium hypochlorite (NaOCl), compared to ultrasonically activated NaOCl and ultrasonically activated NaOCl that had undergone intracanal heating NaOCl. Materials and Methods: A total of 60 freshly extracted human mandibular premolars underwent root sample length standardization (18 mm), root canal preparation and, based on the irrigation method employed, were randomly and equally assigned to three study groups, composed of root samples treated with ultrasonically activated NaOCl, ultrasonically activated NaOCl that had undergone intracanal heating and traditionally applied NaOCl. The root specimens were subsequently fixated with 4% buffered formalin solution and decalcified in Morse liquid. A total often 6-micron-thick serial cross-sections were obtained, dyed using hematoxylin and eosin and examined through an optical microscope at 40×, 100×, and 200×. Results: Ultrasonically activated NaOCl that had undergone intracanal heating showed a significantly smaller amount of debris compared to ultrasonically activated and traditionally applied NaOCl groups (p value < 0.05). Conclusions: Root canal cleanliness saw significant enhancements by ultrasonically activated NaOCl that had undergone intracanal heating.Keywords
This publication has 24 references indexed in Scilit:
- Antibacterial Efficacy of a New Sonic Irrigation Device for Root Canal DisinfectionJournal of Endodontics, 2016
- Nonsurgical management of complex endodontic cases with several periapical lesions: a case seriesGiornale Italiano di Endodonzia, 2016
- Antibiofilm activity of three irrigation protocols activated by ultrasonic, diode laser or Er:YAG laser in vitroInternational Endodontic Journal, 2014
- La preparazione dell’istmo coronale: una procedura fondamentale per un successo a lungo termineGiornale Italiano di Endodonzia, 2012
- Microscopio operatorio: diffusione e limitiGiornale Italiano di Endodonzia, 2012
- IG-File: un nuovo strumento per l’ottimizzazione della detersione canalare e per la misurazione del diametro apicaleGiornale Italiano di Endodonzia, 2011
- Tissue Dissolution by Sodium Hypochlorite: Effect of Concentration, Temperature, Agitation, and SurfactantJournal of Endodontics, 2010
- Review of Contemporary Irrigant Agitation Techniques and DevicesJournal of Endodontics, 2009
- Root Canal IrrigantsJournal of Endodontics, 2006
- Effect of temperature on collagen-dissolving ability of sodium hypochlorite endodontic irrigantOral Surgery, Oral Medicine, Oral Pathology, 1980