Monitoring Ambient Nitrate Radical by Open-Path Cavity-Enhanced Absorption Spectroscopy
- 31 July 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (16) , 10687-10693
Abstract
We describe an open-path cavity-enhanced absorption spectroscopy (OP-CEAS) technique for the ambient measurement of nitrate radicals (NO3) near 662 nm. Compared with the closed type of CEAS system with a sampling line, the OP-CEAS features high accuracy due to the lack of NO3 loss in the sampling line and cavity. On the basis of a 0.84 m long open-path cavity, the effective absorption length of ∼5 km is achieved by mirrors with a reflectivity of 0.99985 at 662 nm. The detection limit of OP-CEAS for the measurement of NO3 is 3.0 pptv (2σ) in 30 s, and the uncertainty is 11–15%. The instrument was successfully applied in a field measurement under low particulate matter (PM) loading conditions. As the sensitivity would be decreased due to strong PM extinction under heavy PM pollution conditions, we highlight the feasibility of this OP-CEAS configuration for field application in clean and moderate PM condition, such as forested regions affected by anthropogenic emissions. This technique is also appropriate for the field detection of other reactive trace gases in future studies.Keywords
Funding Information
- Peking University
- Ministry of Science and Technology of the People's Republic of China (2017YFC0209400)
- China Postdoctoral Science Foundation (2018M641095, 2019T120023)
- National Natural Science Foundation of China (91544225, 91844301)
This publication has 37 references indexed in Scilit:
- Wavelength-Resolved Optical Extinction Measurements of Aerosols Using Broad-Band Cavity-Enhanced Absorption Spectroscopy over the Spectral Range of 445–480 nmAnalytical Chemistry, 2013
- An aircraft based three channel broadband cavity enhanced absorption spectrometer for simultaneous measurements of NO3, N2O5 and NO2Atmospheric Measurement Techniques, 2011
- The HITRAN 2004 molecular spectroscopic databaseJournal of Quantitative Spectroscopy and Radiative Transfer, 2005
- A thermal dissociation–chemical ionization mass spectrometry (TD‐CIMS) technique for the simultaneous measurement of peroxyacyl nitrates and dinitrogen pentoxideJournal of Geophysical Research: Atmospheres, 2004
- Nitrogen oxides in the nocturnal boundary layer: Simultaneous in situ measurements of NO3, N2O5, NO2, NO, and O3Journal of Geophysical Research: Atmospheres, 2003
- The temperature and pressure dependence of the absorption cross-sections of NO2 in the 250–800 nm region measured by Fourier-transform spectroscopyJournal of Photochemistry and Photobiology A: Chemistry, 2002
- A new method for the atmospheric detection of the nitrate radical (NO3)Atmospheric Environment, 2000
- Measurement of atmospheric NO3 1. Improved removal of water vapour absorption features in the analysis for NO3Geophysical Research Letters, 1996
- The nitrate radical: Physics, chemistry, and the atmosphereAtmospheric Environment. Part A. General Topics, 1991
- Detection of NO3 in the polluted troposphere by differential optical absorptionGeophysical Research Letters, 1980