A review of the relationship between peak currents of the first and subsequent strokes in the same flash
Authors:
- 2 October 2022
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 10-13
Abstract
Three distinct data sets are analyzed in terms of probability of flashes having subsequent strokes with higher peak currents than the first stroke in the flash. This type of flashes may have some implication in the shielding failure rate of transmission lines. For three distinct data sets we obtained about 30 % of flashes with a ratio I sub /I 1 >1. For about 10 % of the flashes the peak current of a subsequent stroke is more the two times the peak of the first stroke, and for about 3 to 4 % of the flashes we obtained a ratio I sub /I l is grater then 3.Keywords
This publication has 6 references indexed in Scilit:
- Global ground strike point characteristics in negative downward lightning flashes – Part 2: Algorithm validationNatural Hazards and Earth System Sciences, 2021
- Ground truth data of atmospheric discharges in correlation with LLS detectionsElectric Power Systems Research, 2020
- First versus subsequent return‐stroke current and field peaks in negative cloud‐to‐ground lightning dischargesJournal of Geophysical Research: Atmospheres, 2008
- IEEE Guide for Improving the Lightning Performance of Transmission Lines2008
- A Combined TOA/MDF Technology Upgrade of the U.S. National Lightning Detection NetworkJournal of Geophysical Research: Atmospheres, 1998
- Lightning subsequent‐stroke electric field peak greater than the first stroke peak and multiple ground terminationsJournal of Geophysical Research: Atmospheres, 1992