The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity
Authors:
- Robinson Ramírez-VélezRobinson Ramírez-Vélez
- Jorge Enrique Correa-BautistaJCJorge Enrique Correa-Bautista
- Katherine González-RuízKGKatherine González-Ruíz
- Alejandra Tordecilla-SandersATAlejandra Tordecilla-Sanders
- Antonio García-HermosoAGAntonio García-Hermoso
- Jacqueline Schmidt-RioValleJSJacqueline Schmidt-RioValle
- Emilio González-JiménezEmilio González-Jiménez
Open Access
- 21 September 2017
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (10) , 1093
Abstract
The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson’s correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t-test, Lin’s concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin’s concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (−5.6 (95%CI −6.4 to −4.8); p < 0.001). In the women, these differences were (−3.6 (95%CI −4.7 to −2.5); p < 0.001). Overall, the bias of the BAI-BF% was −4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups.Keywords
This publication has 37 references indexed in Scilit:
- Evaluating and adapting the Mediterranean diet for non-Mediterranean populations: A critical appraisalNutrition Reviews, 2013
- Sex differences in adipose tissueAdipocyte, 2013
- Body Adiposity Index and Cardiovascular Health Risk Factors in Caucasians: A Comparison with the Body Mass Index and OthersPLOS ONE, 2013
- The Body Adiposity Index (Hip Circumference ÷ Height1.5) Is Not a More Accurate Measure of Adiposity Than Is BMI, Waist Circumference, or Hip CircumferenceObesity, 2012
- Changes in body composition during weight loss in obese subjects in the NUGENOB study: Comparison of bioelectrical impedance vs. dual-energy X-ray absorptiometryDiabetes & Metabolism, 2011
- A Better Index of Body AdiposityObesity, 2011
- Male and female differences in variability with estimating body fat composition using skinfold calipersJournal of Chiropractic Medicine, 2010
- Assessing body fat changes during moderate weight loss with anthropometry and bioelectrical impedanceObesity Research & Clinical Practice, 2009
- The incidence of co-morbidities related to obesity and overweight: A systematic review and meta-analysisBMC Public Health, 2009
- Assessment methods in human body compositionCurrent Opinion in Clinical Nutrition and Metabolic Care, 2008