The Effect of Lesion Size and Activity Concentration on Image Quality in PET/CT Imaging: A Phantom Study
Open Access
- 12 November 2025
- journal article
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 148 (3)
Abstract
In this study, the National Electrical Manufacturers Association (NEMA) image quality tests were conducted using the General Electric Discovery 690 model — a hybrid system of positron emission tomography/computed tomography. Quantitative evaluation of image quality within this model primarily involves the use of parameters such as contrast (C), contrast-to-noise ratio (CNR), and contrast recovery coefficient (CRC). These metrics are considered essential performance indicators, particularly in standardized assessment protocols such as those proposed by NEMA. The objective of this study was to evaluate image quality in a NEMA positron emission tomography phantom using 18F-FDG at different signal-to-background (S/Bg) ratios and varying activity concentrations, and to determine the minimum detectable lesion size. Positron emission tomography images were acquired using a NEMA 2012/IEC 2008 phantom with 18F-FDG at S/Bg ratios of 4:1, 6:1, and 8:1, across decreasing activity concentrations ranging from 9.98 to 1.93 MBq/kg. At an S/Bg ratio of 4:1, activity concentrations below 3.90 MBq/kg (as well as at 6:1 below 2.76 MBq/kg) resulted in CNR values less than 5, falling below the detectability threshold. Regarding the CRC [%] values, for the 4:1 ratio, lesions with diameters of 13 and 10 mm fell outside the acceptable limits at concentrations below 2.89 MBq/kg. Similarly, for the 6:1 ratio, lesions with a diameter of 10 mm exceeded these limits at concentrations below 5.29 MBq/kg. Multiple acquisitions were performed at different ratios and activity levels, and the lesion detectability for each condition was determined based on the Rose criterion (CNR ≥ 5).Keywords
This publication has 32 references indexed in Scilit:
- Influence of reconstruction techniques on PET/CT image quality and quantitative accuracy: a phantom studyRadiation Detection Technology and Methods, 2023
- FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0European Journal of Nuclear Medicine and Molecular Imaging, 2014
- PET quantification: strategies for partial volume correctionClinical and Translational Imaging, 2014
- Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0Annals of Nuclear Medicine, 2014
- Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of viewAnnals of Nuclear Medicine, 2013
- Partial volume correction strategies for quantitative FDG PET in oncologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Partial Volume Correction Strategies in PETPET Clinics, 2007
- Correction for Partial Volume Effects in Emission Tomography2006
- Model observers for assessment of image quality.Proceedings of the National Academy of Sciences, 1993
- The Visual Process1973