Radiation burden to paediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital.
Authors:
- J GeleijnsJGJ Geleijns
- H C HolscherHHH C Holscher
- J WeststrateJWJ Weststrate
- H M ZonderlandHZH M Zonderland
- J ZoeteliefJZJ Zoetelief
- 1 August 1999
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 72 (860) , 763-772
Abstract
Micturating cystourethrography (MCU) examinations of paediatric patients in a major Dutch children's hospital (JKZ) were evaluated to generate quantitative information on effective dose (E). A standard examination involves three radiographs plus fluoroscopy. Observed total dose-area product (DAP) for 84 children increased, on average, with increasing age class from 0.2 to 2.2 Gy cm2. In 11 cases, separate DAP per view was measured; enabling determination, per view, of organ (CF) and effective (CE) dose conversion factors, i.e. dose per unit of DAP. Monte Carlo simulation of photon transport in male and female mathematical phantoms was applied for newborn, 1 year, 5 year, 10 year and 15-year-old patients, and interpolated for other ages. CE per view decreases with increasing age class, yielding about a factor of 10 difference between the extremes of the range. Female values are usually some 20-30% above male ones. CE for one of the views appeared to be representative for the complete examination and was used to estimate total E for each patient. Averaged per age class, E remains approximately constant at 0.3-0.4 mSv, although a tendency to increase with increasing age exists, for females in particular. Within an age class, individual patients may differ in E by a factor of two up to six. Stomach, lower large intestine, bladder wall, liver and ovaries receive relatively high doses. Compared with published data and DAP measured in a few other Dutch hospitals, the radiation burden of MCU is low at the JKZ. This indicates a good degree of optimization with respect to radiation protection (e.g. modern equipment, increased tube voltage, fast film-screen combination).Keywords
This publication has 4 references indexed in Scilit:
- The radiation dose to children from X-ray examinations of the pelvis and the urinary tractBritish Journal of Radiology, 1995
- Radiation doses to paediatric patients undergoing micturating cystourethrography examinations and potential reduction by radiation protection optimizationBritish Journal of Radiology, 1995
- Calculation of dose conversion factors for posterior–anterior chest radiography of adults with a relatively high-energy X-ray spectrumBritish Journal of Radiology, 1994
- Results of a survey of doses to paediatric patients undergoing common radiological examinationsBritish Journal of Radiology, 1992