Clinical Utility of a Feedback Device in High-Quality Cardiopulmonary Resuscitation: The Guardian Angel
Authors:
- Jaime Fernández-SarmientoJFJaime Fernández-Sarmiento
- Andrés Rolando Sanmiguel-BenavidesASAndrés Rolando Sanmiguel-Benavides
- Juan Pablo ContrerasJCJuan Pablo Contreras
- Alirio BastidasABAlirio Bastidas
- Juan Carlos TrujilloJTJuan Carlos Trujillo
- Juanita UribeJUJuanita Uribe
- Daniel Botero-RosasDBDaniel Botero-Rosas
- Eduardo Tuta-QuinteroETEduardo Tuta-Quintero
Open Access
- 9 April 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (8) , 2839
Abstract
Background/Objectives: High-quality cardiopulmonary resuscitation (CPR) is essential for improving clinical outcomes in patients experiencing cardiac arrest. Feedback devices designed to guide CPR must offer real-time feedback on chest compression quality for use by both medical personnel and laypersons. To describe the impact of using an infrared-based device to provide feedback on chest compression quality during CPR performed by healthcare personnel. Methods: A before-and-after study conducted in a simulated hospital from February 2019 to February 2020 evaluated the difference in the percentage of adequate chest compressions in depth and rate. This was assessed by comparing the number of adequate compressions to the total performed in one minute, both with and without the use of a feedback device. Results: A total of 90 participants were recruited, with an average age of 31.2 years (SD: 8.86), of which 60% (54/90) were women. In infants and schoolchildren/adults, high-quality compressions improved by 66% (85% vs. 19%; p < 0.001) and 54% (79% vs. 25%; p < 0.001), respectively, when guided by the GA compared to the control group. In participants without training and experience in CPR, the use of the Guardian Angel achieved high-quality compressions of 45% (10/22) and 66% (25/42), respectively, when evaluating depth for the schoolchildren/adults group. The use of the device during CPR, even in situations of moderate or severe fatigue, resulted in an improvement in high-quality compressions in terms of frequency, reaching 73% (16/22) in infants and 68% (15/22) in schoolchildren/adults. Conclusions: The Guardian Angel improves both the frequency and depth of compressions in participants without previous CPR experience or training. Additionally, the device demonstrated notable improvements in compression frequency, even in situations of moderate or severe fatigue.Keywords
Funding Information
- Universidad de La Sabana (MED-236-2018)
- Fundación Cardioinfantil—Instituto Cardiología
This publication has 25 references indexed in Scilit:
- Use of CPR feedback devices in resuscitation training: A systematic review and meta-analysis of randomized controlled trialsResuscitation Plus, 2025
- Pediatric Chest Compression Improvement Via Augmented Reality Cardiopulmonary Resuscitation Feedback in Community General Emergency Departments: A Mixed-Methods Simulation-Based Pilot StudyThe Journal of Emergency Medicine, 2023
- Cardiac Arrest Quality Improvement: A Single-Center Evaluation of Resuscitations Using Defibrillator, Feedback Device, and Survey DataJournal of Emergency Nursing, 2022
- Survival to Intensive Care Unit Discharge Among in-Hospital Cardiac Arrest Patients by Applying Audiovisual Feedback DeviceESC Heart Failure, 2021
- Visual attention during pediatric resuscitation with feedback devices: a randomized simulation studyPediatric Research, 2021
- Effect of real-time and post-event feedback in out-of-hospital cardiac arrest attended by EMS — A systematic review and meta-analysisResuscitation Plus, 2021
- The REDCap consortium: Building an international community of software platform partnersJournal of Biomedical Informatics, 2019
- A flexible pressure sensor could correctly measure the depth of chest compression on a mattressThe American Journal of Emergency Medicine, 2016
- Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trialBMJ, 2011
- The use of CPR feedback/prompt devices during training and CPR performance: A systematic reviewResuscitation, 2009