Appraisal of the New Posture Analyzing and Virtual Reconstruction Device (PAViR) for Assessing Sagittal Posture Parameters: A Prospective Observational Study
Open Access
- 5 September 2022
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (17) , 11109
Abstract
The purpose of this study was to report the clinical validation of the posture analyzing and virtual reconstruction device (PAViR) system, focusing on the accuracy of sagittal spinal parameters, compared with the EOS imaging system. Seventy patients diagnosed with segmental and somatic dysfunction were recruited between February 2020 and November 2020. Each patient was examined using the EOS imaging system and PAViR; the sagittal parameters of human body posture [forward head posture (FHP), T1 tilt angle (T1t), knee flexion angle (KF), lumbar lordosis angle (LL), and pelvic tilt angle (PT)] were analyzed to verify the correlation between the results of the two devices. The median differences in the results of the two devices showed significant differences in FHP (T4-frontal head and T4-auditory canal), T1t, and PT. In the correlation analysis, the values of FHP (C7-auditory canal, T4-frontal head, and T4-auditory canal), T1t, and PT showed a moderate correlation between the two devices (r = 0.741, 0.795, 0.761, 0.621, and 0.692, respectively) (p < 0.001). The KF and LL was fairly correlated (r = 0.514 and 0.536, respectively) (p = 0.004, both). This study presents the potential of a novel skeletal imaging system without radiation exposure, based on a 3D red-green-blue-depth camera (PAViR), as a next-generation diagnostic tool by estimating more accurate parameters through continuous multi-data-based upgrades with artificial intelligence technology.Keywords
Funding Information
- Rehabilitation Institute of Neuromuscular Disease, Yonsei University College of Medicine
This publication has 26 references indexed in Scilit:
- Background foreground segmentation with RGB-D Kinect data: An efficient combination of classifiersJournal of Visual Communication and Image Representation, 2014
- Assessment of the axial rotation of the pelvis with the EOS® imaging system: intra- and inter-observer reproducibility and accuracy studyEuropean Journal of Orthopaedic Surgery & Traumatology, 2013
- Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D/3D imaging systemThe Spine Journal, 2012
- Evaluation of the reproducibility of the formetric 4D measurements for scoliosisScoliosis and Spinal Disorders, 2010
- Diagnostic Imaging of Spinal DeformitiesSpine, 2010
- 3D postural balance with regard to gravity line: an evaluation in the transversal plane on 93 patients and 23 asymptomatic volunteersEuropean Spine Journal, 2009
- Reliability of the Visual Assessment of Cervical and Lumbar Lordosis: How Good Are We?Spine, 2003
- Moiré topography: alternative technique in health careOptics and Lasers in Engineering, 2003
- Investigation of the Validity of Postural Evaluation Skills in Assessing Lumbar Lordosis Using Photographs of Clothed SubjectsJournal of Orthopaedic & Sports Physical Therapy, 1990
- The Clinical Value of Moiré Topography in the Management of ScoliosisSpine, 1986