In Vivo Detection of Acinar Microstructural Changes in Early Emphysema with3He Lung Morphometry

Authors:

Abstract
In vivo helium 3 lung morphometry has greater sensitivity to early emphysematous changes than does low-dose CT or traditional pulmonary function testing (PFT), and this modality can be used to detect significant changes in acinar airway geometry, even in individuals with clinically normal PFT results. PurposeTo quantitatively characterize early emphysematous changes in the lung microstructure of current and former smokers with noninvasive helium 3 (3He) lung morphometry and to compare these results with the clinical standards, pulmonary function testing (PFT) and low-dose computed tomography (CT).Materials and MethodsThis study was approved by the local institutional review board, and all subjects provided informed consent. Thirty current and former smokers, each with a minimum 30-pack-year smoking history and mild or no abnormalities at PFT, underwent 3He lung morphometry. This technique is based on diffusion MR imaging with hyperpolarized 3He gas and yields quantitative localized in vivo measurements of acinar airway geometric parameters, such as airway radii, alveolar depth, and number of alveoli per unit lung volume. These measurements enable calculation of standard morphometric characteristics, such as mean linear intercept and surface-to-volume ratio.ResultsNoninvasive 3He lung morphometry was us...