Efficacy of Enhanced Environmental Cleaning/Disinfection Using Pulsed Xenon Ultraviolet Light in Preventing Outbreaks of Methicillin-Resistant Staphylococcus aureus in Neonatal Intensive Care Units
Open Access
- 4 March 2025
- journal article
- research article
- Published by MDPI AG in Epidemiologia
- Vol. 6 (1) , 12
Abstract
Background/Objectives: In recent years, non-contact room disinfection devices using ultraviolet light and hydrogen peroxide have emerged as disinfection methods. However, data on their usefulness in neonatal intensive care units (NICUs) are limited. Therefore, the aim of the present study was to evaluate the effectiveness of environmental disinfection in controlling methicillin-resistant Staphylococcus aureus (MRSA) outbreaks in a NICU/growing care unit (GCU). Methods: Daily cleaning/disinfection of the patient environment was changed from using a cloth containing quaternary ammonium salts to an agent containing ethanol and surfactant, and terminal cleaning with a pulsed xenon ultraviolet light (PX-UV) non-contact disinfection device was added for patients with confirmed MRSA and those on contact precautions. MRSA incidence and environmental culture results were then compared before and after the method change. Results: The MRSA infection rate was 2.81/1000 patient days before the method change and 0.90/1000 patient days after the change (p = 0.008). Environmental cultures were positive in 12/137 (8.8%) before the change and 0 after the change. There were no adverse events in the neonates due to PX-UV irradiation of the environment. Conclusions: Daily cleaning and disinfection with ethanol and surfactant-containing cleaning disinfectants and a final cleaning with a PX-UV non-contact disinfection device reduced environmental MRSA contamination. In addition to adherence to hand hygiene and contact precautions, reducing MRSA present in the environment may contribute to MRSA control in NICUs and GCUs.Keywords
This publication has 51 references indexed in Scilit:
- Risk factors for methicillin-resistant Staphylococcus aureus colonization in the neonatal intensive care unit: A systematic review and meta-analysisAmerican Journal of Infection Control, 2017
- Is the pulsed xenon ultraviolet light no-touch disinfection system effective on methicillin-resistant Staphylococcus aureus in the absence of manual cleaning?American Journal of Infection Control, 2015
- Improving hand hygiene compliance in health care workers: Strategies and impact on patient outcomesAmerican Journal of Infection Control, 2013
- Disinfectants used for environmental disinfection and new room decontamination technologyAmerican Journal of Infection Control, 2013
- Does improving surface cleaning and disinfection reduce health care-associated infections?American Journal of Infection Control, 2013
- Hospital cleaning in the 21st centuryEuropean Journal of Clinical Microbiology & Infectious Diseases, 2011
- Environmental Cleaning Intervention and Risk of Acquiring Multidrug-Resistant Organisms From Prior Room OccupantsArchives of internal medicine (1960), 2011
- Reduction in infection risk through treatment of microbially contaminated surfaces with a novel, portable, saturated steam vapor disinfection systemAmerican Journal of Infection Control, 2009
- An evaluation of patient area cleaning in 3 hospitals using a novel targeting methodologyAmerican Journal of Infection Control, 2006
- Role of Environmental Contamination as a Risk Factor for Acquisition of Vancomycin-Resistant Enterococci in Patients Treated in a Medical Intensive Care UnitArchives of internal medicine (1960), 2003