Cryogenic Preservation of Low-Quality Human Semen

Authors:
  • TKT. Kobayashi
    T. Kobayashi
  • HLH. K. Lee
    H. K. Lee
  • WWW. K. Won
    W. K. Won
  • TOT. Oda
    T. Oda
  • YIY. Izumi
    Y. Izumi
  • TOT. Ohono
    T. Ohono
  • RIR. Iizuka
    R. Iizuka

Abstract
The article describes the technical strategies for clinical cryogenic preservation of low-quality human semen. To compensate for sperm dilution resulting from the use of a cryogenic medium, ejaculated semen was concentrated before freezing by means of continuous-step density gradient centrifugation. Freezing was simplified by employing the carbon dioxide pellet method with KS-II cryogenic medium, which contains Pluronic F-68, a nonionic detergent, to solubilize egg yolk (a major cryogenic protectant). Semen of less than 50% motility (n = 23) was processed and then cryogenically preserved. Sperm concentration was increased by a factor of 1.8 .+-. 0.96 (n = 23). Sperm motility was improved from 35.9% .+-. 13.9% to 69.4% .+-. 10.8%. Even after thawing 59.4% .+-. 17.5% motility remained, with a mean survival rate of 85% .+-. 14%. The concentration of sperm and improved sperm motility by the use of the continuous-step density gradient and the high survival rate ensured by the carbon dioxide pellet method with KS-II cryogenic medium compensated for the lowering of sperm quality during cryogenic preservation.

This publication has 6 references indexed in Scilit: