Picosecond Electron-Optical Chronography
Authors:
- 15 March 1972
- journal article
- research article
- Published by AIP Publishing in Applied Physics Letters
- Vol. 20 (6) , 219-221
Abstract
An image‐tube streak camera has been further developed to be completely electronically operated, with an improved instrumental time resolution of <4 psec and negligible background. With a trigger pulse of 10 V and a rise time of 1 nsec, the over‐all system triggering jitter is <200 psec. The camera has been used to measure the durations of ultrashort pulses (2–3 psec) from a mode‐locked dye laser.Keywords
This publication has 12 references indexed in Scilit:
- Frequency-Tunable Transform-Limited Picosecond Dye-Laser PulsesApplied Physics Letters, 1971
- Direct measurement of duration and background energy content of dye laser picosecond pulsesOptics Communications, 1971
- IMAGE-CONVERTER STREAK CAMERA WITH PICOSECOND RESOLUTIONApplied Physics Letters, 1971
- Direct linear measurement of ultrashort light pulses with a picosecond streak cameraOptics Communications, 1971
- NANOSECOND GATING OF AN IMAGE INTENSIFIER CAPABLE OF TRIGGERED PICOSECOND PHOTOGRAPHYApplied Physics Letters, 1970
- Picosecond pulses from mode-locked dye lasersPhysics Letters A, 1969
- Time Resolution of an Image Converter Camera in Streak OperationThe Journal of Photographic Science, 1969
- Passive mode-locking of flashlamp pumped Rhodamine dye-lasersOptical and Quantum Electronics, 1969
- A simple laser-triggered spark gap for kilovolt pulses of accurately variable timingOptical and Quantum Electronics, 1969
- A dynamic electron image information storeJournal of Scientific Instruments, 1966