Contact Index–Guided Pulsed Field Ablation: A Two‐Phase Validation of the Impedance Change Threshold to Prevent Acute Pulmonary Vein Gaps
Open Access
- 4 April 2026
- journal article
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (2)
Abstract
Background: Pulsed field ablation (PFA) for atrial fibrillation (AF) requires adequate catheter–tissue contact. The Contact Index visualizes impedance change for the pentaspline catheter, but a validated contact threshold is unknown. Objective: The objective of this study is to define an impedance‐change cutoff that predicts sufficient contact to prevent acute pulmonary vein gaps (PVG) during pulmonary vein isolation (PVI), and to validate Contact–Index‐guided PVI. Methods: A prospective, single‐center, two‐phase study was performed. Phase 1 ( n = 10) measured impedance change (%) at eight antral segments per vein immediately before PFA in basket and flower configurations; the larger per‐segment value was analyzed. Post‐PVI high‐density voltage mapping (PVG ≥ 0.5 mV) was the reference; a receiver operating characteristic analysis identified the cutoff. Phase 2 ( n = 26) delivered energy only when all target splines met/exceeded the cutoff value obtained from Phase 1. Results: In Phase 1, PVG occurred in 13/320 segments across 2/10 patients (4/40 veins). Impedance change was lower at PVG‐positive than PVG‐negative segments (median 2 [0–6.5]% vs. 24 [17–32]%, p < 0.001). The cutoff value obtained from Phase 1 was ≥ 10% (area under the curve 0.99; sensitivity 100%; specificity 92.1%). In Phase 2, enforcing ≥ 10% yielded no patient‐level PVG (0/26 vs. 2/10; p = 0.07) and fewer gaps per vein (0/104 vs. 4/40; p = 0.005) and per segment (0/832 vs. 13/320; p < 0.001) compared with Phase 1. Procedure time, PVI time, fluoroscopy time, and total applications were similar between phases. Conclusions: An impedance‐change threshold of ≥ 10% on the Contact Index reliably indicates adequate contact with the pentaspline catheter and, when enforced, reduces acute PVG without prolonging procedures.Keywords
This publication has 16 references indexed in Scilit:
- In vivo assessment of catheter-tissue contact using tissue proximity indication and its impact on cardiac lesion formation in pulsed field ablationHeart Rhythm, 2024
- Where is the gap after a 90 W/4 s very‐high‐power short‐duration ablation of atrial fibrillation?: Association with the left atrial‐pulmonary vein voltage and wall thicknessJournal of Arrhythmia, 2024
- Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial FibrillationNew England Journal of Medicine, 2023
- Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal TrialCirculation, 2023
- Personalized pulmonary vein antrum isolation guided by left atrial wall thickness for persistent atrial fibrillationEP Europace, 2023
- Impedance Imaging of Cells and Tissues: Design and ApplicationsBME Frontiers, 2022
- Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial FibrillationJACC, 2019
- The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolationJournal of Interventional Cardiac Electrophysiology, 2019
- High-voltage zones within the pulmonary vein antra: Major determinants of acute pulmonary vein reconnections after atrial fibrillation ablationJournal of Interventional Cardiac Electrophysiology, 2017
- Endocardial impedance mapping during circumferential pulmonary vein ablation of atrial fibrillation differentiates between atrial and venous tissueHeart Rhythm, 2006