Fetal biometry: a comparison between experienced sonographers and automated measurements
- 1 January 2009
- journal article
- research article
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 22 (1) , 43-50
Abstract
Objective. We compared the performance between sonographers and automated fetal biometry measurements (Auto OB) with respect to the following measurements: biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL). Methods. The first set of experiments involved assessing the performance of Auto OB relative to the five sonographers, using 240 images for each user. Each sonographer made measurements in 80 images per anatomy. The second set of experiments compared the performance of Auto OB with respect to the data generated by the five sonographers for inter-observer variability (i.e., sonographers and clinicians) using a set of 10 images per anatomy. Results. Auto OB correlated well with manual measurements for BPD, HC, AC and FL (r > 0.98, p < 0.001 for all measurements). The errors produced by Auto OB for BPD is 1.46% (σ = 1.74%), where σ denotes standard deviation), for HC is 1.25% (σ = 1.34%), for AC is 3% (σ = 6.16%) and for FL is 3.52% (σ = 3.72%). In general, these errors represent deviations of less than 3 days for fetuses younger than 30 weeks, and less than 7 days for fetuses between 30 and 40 weeks of age. Conclusion. The measurements produced by Auto OB are comparable to the measurements done by sonographers.Keywords
This publication has 13 references indexed in Scilit:
- Comments on: A methodology for evaluation of boundary detection algorithms on medical imagesIEEE Transactions on Medical Imaging, 2004
- Ultrasonographic prediction of term birth weight: How accurate is it?American Journal of Obstetrics and Gynecology, 2003
- Fetal Biometry: Clinical, Pathological, and Technical ConsiderationsObstetrical & Gynecological Survey, 2001
- Transducer user syndrome: an occupational hazard of the ultrasonographerEuropean Journal of Ultrasound, 1999
- Occupational health hazards to the ultrasonographer and their possible preventionJournal of the American Society of Echocardiography, 1997
- Interactive automatic fetal head measurements from ultrasound images using multimedia computer technologyUltrasound in Medicine & Biology, 1997
- A methodology for evaluation of boundary detection algorithms on medical imagesIEEE Transactions on Medical Imaging, 1997
- Automatic fetal head measurements from sonographic imagesAcademic Radiology, 1996
- Automatic measurements of fetal long bones. A feasibility study.Journal of Ultrasound in Medicine, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986