The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation
Open Access
- 1 January 2015
- journal article
- research article
- Published by Medknow in Journal of Conservative Dentistry
- Vol. 18 (3) , 218-22
Abstract
Aims: To observe and study the effect of multiple autoclave sterilization cycles, on the surface of nickel-titanium (NiTi) files. Materials and Methods: The file used for this study was the M two file (VDW) and ProTaper (Dentsply). The apical 5 mm of the files were attached to a silicon wafer and subjected to autoclave cycles under standardized conditions. They were scanned with an AFM after 1, 5, and 10 cycles. The unsterilized files were used as control, before start of the study. Three vertical topographic parameters namely maximum height (MH), root mean square (RMS) of surface roughness, and arithmetic mean roughness (AMR)were measured with the atomic force microscope (AFM). Analysis of variance along with Tukey's test was used to test the differences. Results: The vertical topographic parameters were higher for both the files, right after the first cycle, when compared with the control (P < 0.01). The surface roughness increased sharply for M two when compared to ProTaper, though ProTaper had a rougher surface initially. Conclusions: The study confirmed that the irregularities present on the surface of the file became more prominent with multiple autoclave cycles, a fact that should be kept in mind during their reuse.Keywords
This publication has 15 references indexed in Scilit:
- The effect of autoclaving on torsional moment of two nickel–titanium endodontic filesInternational Endodontic Journal, 2011
- Evaluation of the Surface Characteristics of Used and New ProTaper Instruments: An Atomic Force Microscopy StudyJournal of Endodontics, 2007
- Effect of heat sterilization on surface characteristics and microstructure of Mani NRT rotary nickel–titanium instrumentsInternational Endodontic Journal, 2006
- Atomic Force Microscopy Study of Stainless-Steel and Nickel-Titanium FilesJournal of Endodontics, 2005
- SEM Observations of Nickel-Titanium Rotary Endodontic Instruments that Fractured During Clinical UseJournal of Endodontics, 2005
- The effect of cleaning procedures on fracture properties and corrosion of NiTi filesInternational Endodontic Journal, 2003
- Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instrumentsInternational Endodontic Journal, 2002
- An overview of nickel–titanium alloys used in dentistryInternational Endodontic Journal, 2000
- Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic filesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1999
- The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloysInternational Endodontic Journal, 1998