Electrical-thermal co-analysis for power delivery networks in 3D system integration
Authors:
- 1 September 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
In this paper, an electrical-thermal co-analysis method for power delivery networks in 3D system integration is proposed. For electrical analysis, temperature-dependent electrical resistivity of conductors is taken into account. For thermal analysis, Joule heating effect due to the current flowing through conductors is considered. The proposed co-analysis method is carried out using Rgen and ChipJoule of IBM EIP Tool Suite. An example of 3D integration system including stacked chips, power delivery network, glass-ceramic substrate, through-silicon vias, controlled collapse chip connections (C4s), underfill material, and TIM is analyzed using the proposed method. The simulation results show that the temperature effect on IR drop can not be neglected. The error of not considering thermal effect on IR drop is about 20% in the example.Keywords
This publication has 6 references indexed in Scilit:
- Device Level Electrothermal Analysis of Integrated Resistors2007
- Parametric thermal modeling of 3D stacked chip electronics with interleaved solid heat spreaders2006
- Electrothermal analysis and optimization techniques for nanoscale integrated circuits2006
- Efficient full-chip thermal modeling and analysis2005
- Electro-thermal circuit simulation using simulator couplingIEEE Transactions on Very Large Scale Integration (VLSI) Systems, 1997
- Computer simulation of integrated circuits in the presence of electrothermal interactionIEEE Journal of Solid-State Circuits, 1976