Practical Experiences with Linear Polarization Measurements
Author:
- 1 April 1977
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 33 (4) , 117-128
Abstract
The linear polarization technique in principle is a convenient and rapid way for determining corrosion rates. In practice, one finds that it is often applied under conditions alien to the assumptions on the basis of which it was derived. This paper will present a series of comparative observations between linear polarization, resistance probe, and weight loss measurements in different systems. The systems studied were: (1) Hydrochloric acid containing acetylenic inhibitors, (2) a two phase system containing hydrocarbon and water saturated with H2S, and (3) tap water containing various inhibitors. An equation will be derived showing the effect of ohmic resistance due to corrosion product buildup. The effect of polarization on the properties of a corrosion product layer will be discussed qualitatively.Keywords
This publication has 18 references indexed in Scilit:
- Corrosion rates from polarization curves: A new methodCorrosion Science, 1973
- The Stern-Geary method. Basic difficulties and limitations and a simple extension providing improved reliabilityCorrosion Science, 1973
- The effect of anodic or cathodic control on linear polarization in non-ideal situationsCorrosion Science, 1973
- Some consideration in determining corrosion rates from linear polarization measurementsCorrosion Science, 1973
- Two-point and three-point methods for the investigation of electrode reaction mechanismsElectrochimica Acta, 1970
- The influence of corrosion product structure on the corrosion rate of Cu-Ni alloysCorrosion Science, 1970
- Linear corrosion kineticsCorrosion Science, 1969
- On the relation between corrosion rate and polarization resistanceCorrosion Science, 1967
- Die Korrosion der Metalle1966
- Electrochemical PolarizationJournal of the Electrochemical Society, 1957