Optimization of a Low-Cost Force Sensor for Spinal Orthosis Applications
Authors:
- 24 July 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (12) , 3243-3250
Abstract
Force sensors have been reported to be reliable for monitoring spinal orthosis compliance in the treatment of scoliosis. However, the current force sensor used for these compliance monitors has certain limitations and drawbacks. A lower cost force sensor with a 55% larger operating force range was chosen for this application, with modifications required to increase its contact surface, improve comfort, and reduce the manufacturing time. Different designs have been considered and described in this paper. A final prototype using a rubberlike material housing with a stiff nub over the sensing area of the original sensor produced a linear, highly sensitive, large surface area, reliable, and robust sensor. It has a sensitivity of 315 mV/N, accuracy 1.9%, repeatability 0.6%, linearity 0.7%, hysteresis 0.8%, dead band 0.0%, point drift 0.5%, temperature drift 2.2% for the temperature range 25 °C- 35 °C, and reproducibility 1.3%. These properties are adequate for measuring forces in a spinal orthosis. The total cost of the sensor with housing is $46 when ordered in quantities of 1000, which reduces the price of the existing sensor by 34%. The manufacturing time of the new sensor was reduced and a preliminary subject trial demonstrated that the new sensor did not have significant temperature effect. This will make force systems more affordable and adaptable for the effective treatment of scoliosis.Keywords
This publication has 19 references indexed in Scilit:
- Effectiveness and outcomes of brace treatment: A systematic reviewPhysiotherapy Theory and Practice, 2011
- A High-Sensitivity Hydraulic Load Cell for Small Kitchen AppliancesSensors, 2010
- Brace Management in Adolescent Idiopathic ScoliosisClinical Orthopaedics and Related Research, 2010
- Load cells in force sensing analysis -- theory and a novel applicationIEEE Instrumentation & Measurement Magazine, 2010
- Sensorized thimble for haptics applications2009
- Improving the Response of a Load Cell by Using Optimal FilteringSensors, 2006
- The magic glove2004
- A Reliable and Accurate Method for Measuring Orthosis Wearing TimeSpine, 2002
- Reliability of F-Scan In-Shoe Measurements of Plantar PressureFoot & Ankle International, 1998
- A low-cost instrumented glove for monitoring forces during object manipulationIEEE Transactions on Rehabilitation Engineering, 1997