Organ and effective dose rate coefficients for submersion exposure in occupational settings
- 24 August 2017
- journal article
- research article
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 56 (4) , 453-462
Abstract
External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.Keywords
This publication has 9 references indexed in Scilit:
- Effective dose rate coefficients for exposure to contaminated soilRadiation and Environmental Biophysics, 2017
- Effective Dose Rate Coefficients for Immersions in Radioactive Air and WaterRadiation Protection Dosimetry, 2016
- Organ doses from environmental exposures calculated using voxel phantoms of adults and childrenPhysics in Medicine & Biology, 2012
- Compendium of Material Composition Data for Radiation Transport Modeling2011
- Conversion Coefficients for Radiological Protection Quantities for External Radiation ExposuresAnnals of the ICRP, 2010
- Preface, Executive Summary and GlossaryAnnals of the ICRP, 2007
- Basic anatomical and physiological data for use in radiological protection: reference valuesAnnals of the ICRP, 2002
- Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.2002
- Air-ground Interface Effect on Gamma-ray Submersion DoseHealth Physics, 1981