Total Power Radiometer for Medical Sensor Applications Using Matched and Mismatched Noise Sources
Open Access
Abstract
This paper presents a simple total power radiometer to noninvasively measure the temperature of the human body. The proposed 3-GHz radiometer consists of an antenna collecting the noise power generated by a target, a low-noise and high-gain receiver amplifying the noise power, and a detector converting the noise power to voltage. A single-pole-triple-throw (SP3T) switch is placed between the antenna and the receiver, while a personal computer is used to control the SP3T switch, collect and process the data such as detector output voltages and physical temperatures of the reference noise sources and the target. The fabricated radiometer shows a good performance agreement with a thermometer in the temperature measurement of water from 25.0 to 43.1 °C. For the accurate prediction of the target temperature, the radiometer is calibrated adaptively to the environment and radiometer variations. For this purpose, two reference noise sources (hot and cold) are proposed using matched and mismatched resistors at room temperature. These resistor-based noise sources offer a reliable performance without complex temperature control systems. Furthermore, they can be easily calibrated in real time by periodically measuring the physical temperatures of the resistors. In addition, the logarithmic detector with wide dynamic range is adopted and logarithmically-fitted based on the measurement results instead of linear approximation, which reduces the error caused by the limited dynamic range of resistor-based noise sources. In order to further increase the accuracy, the performance imbalances between ports in the SP3T switch are also taken into account by employing offsets in the radiometer output voltages.Keywords
This publication has 20 references indexed in Scilit:
- Toward wearable wireless thermometers for internal body temperature measurementsIEEE Communications Magazine, 2014
- Uncertainty of Radiometer Calibration Loads and Its Impact on Radiometric MeasurementsIEEE Transactions on Microwave Theory and Techniques, 2014
- A Study of Compensation for Temporal and Spatial Physical Temperature Variation in Total Power RadiometersIEEE Sensors Journal, 2012
- Improved Radiometric Performance Attained by an Elliptical Microwave Antenna With SuctionIEEE Transactions on Biomedical Engineering, 2011
- Towards Core Body Temperature Measurement via Close Proximity Radiometric SensingIEEE Sensors Journal, 2011
- DESIGN OF MEDICAL RADIOMETER FRONT-END FOR IMPROVED PERFORMANCEProgress In Electromagnetics Research B, 2011
- Thermal Microwave Radiation for Subsurface Absolute Temperature MeasurementActa Physica Polonica A, 2010
- Development and Calibration of SMOS Reference RadiometerIEEE Transactions on Geoscience and Remote Sensing, 2007
- Two-load radiometer precision and accuracyIEEE Transactions on Geoscience and Remote Sensing, 2005
- Non-invasive estimation of hyperthermia temperatures with ultrasoundInternational Journal of Hyperthermia, 2005