Dynamically applied B1+ shimming solutions for non‐contrast enhanced renal angiography at 7.0 tesla
Open Access
- 22 March 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (1) , 114-126
Abstract
The purpose of this study was to detail a strategy for performing non‐contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B management, these studies can be successfully performed at ultrahigh field within local specific absorption rate constraints. An inversion prepared gradient echo acquisition, standard for non‐contrast renal magnetic resonance angiography studies, required radiofrequency pulse specific B shimming solutions to be dynamically applied to address the field dependent increases in both B0 and B inhomogeneity as well as to accommodate limitation in available power. By using more efficient B shimming solutions for the inversion preparation and more homogeneous solutions for the excitation, high quality images of the renal arteries were obtained without venous and background signal artifacts while working within hardware and safety constraints. Finite difference time domain simulations confirmed in vivo measurements with respect to B distributions and homogeneity for the range of shimming strategies used and allowed the calculation of peak local specific absorption rate values normalized by input power and B. Increasing B homogeneity was accompanied by decreasing local specific absorption rate per Watt and increasing maximum local specific absorption rate per [B]2, which must be considered, along with body size and respiratory rate, when finalizing acquisition parameters for a given individual. Magn Reson Med, 2013.Keywords
This publication has 23 references indexed in Scilit:
- Renal Transplant: Nonenhanced Renal MR Angiography with Magnetization-prepared Steady-State Free PrecessionRadiology, 2009
- Non–Contrast-Enhanced MR Imaging of Renal Artery Stenosis at 1.5 TeslaMagnetic Resonance Imaging Clinics of North America, 2009
- A geometrically adjustable 16‐channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 TeslaMagnetic Resonance in Medicine, 2008
- Renal Artery Assessment with Nonenhanced Steady-State Free Precession versus Contrast-enhanced MR AngiographyRadiology, 2007
- Steady‐state free precession MRA of the renal arteries: Breath‐hold and navigator‐gated techniques vs. CE‐MRAJournal of Magnetic Resonance Imaging, 2007
- Nephrogenic Systemic FibrosisJournal of the American Society of Nephrology, 2006
- Gadolinium – a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?Nephrology Dialysis Transplantation, 2006
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Nephrogenic Fibrosing DermopathyThe American Journal of Dermatopathology, 2001
- The NMR phased arrayMagnetic Resonance in Medicine, 1990