Abstract
A CMOS integrated low-power polar demodulator for electrical bioimpedance spectroscopy is proposed. This polar demodulator extracts magnitude and phase of tissue's impedance. Two adaptive self-sampling schemes, namely zero-time sampling (ZTS) and peak-time sampling (PTS), are proposed to efficiently extract the magnitude of impedance. Since ZTS scheme reuses clock signals used in the XOR-based phase-extracting circuit, low-power consumption is achieved. When ZTS scheme is used, magnitude error increases as frequency of the injected sinusoidal signal increases. Instead of ZTS scheme, PTS scheme is used when the signal above 100 kHz is injected. Targeting 1-kHz to 2.048-MHz frequency range, the proposed demodulator designed in a 0.25-im CMOS process consumes 10.3 mW at its maximum with magnitude and phase errors of 1.0% and 1.3°, respectively.Keywords
This publication has 11 references indexed in Scilit:
- A low-power polar demodulator for impedance spectroscopy based on a novel sampling scheme2015
- A Wideband Low-Distortion CMOS Current Driver for Tissue Impedance AnalysisIEEE Transactions on Circuits and Systems II: Express Briefs, 2015
- High-throughput impedance spectroscopy biosensor array chipPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2014
- A CMOS Magnitude/Phase Measurement Chip for Impedance SpectroscopyIEEE Sensors Journal, 2013
- Analyses of single-stage complementary self-biased CMOS differential amplifiers2012
- A CMOS Instrumentation Amplifier With 90-dB CMRR at 2-MHz Using Capacitive Neutralization: Analysis, Design Considerations, and ImplementationIEEE Transactions on Circuits and Systems I: Regular Papers, 2010
- A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor ArrayIEEE Transactions on Biomedical Circuits and Systems, 2010
- Optimal electrode placement and frequency range selection for the detection of lung water using Bioimpedance Spectroscopy2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2007
- Electrical Impedance Spectroscopy of the Human ProstateIEEE Transactions on Biomedical Engineering, 2007
- Dispersion and Absorption in Dielectrics I. Alternating Current CharacteristicsThe Journal of Chemical Physics, 1941