Study on AC Transient Overvoltage Suppression of LCC-HVDC Sending End System Based on DC Current Control Optimization
Authors:
- 1 April 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2419-2424
Abstract
The receiving end system AC fault of the line-commutated-converter based high voltage direct current (LCC-HVDC) system will lead to commutation failure (CF) in inverter. During the fault and its recovery, AC transient low voltage and transient overvoltage (TOV) will occur in the sending end system. The TOV has the risk of triggering the disorderly off-grid of the nearby renewable power generations, and in a serious situation, it will threaten the power system can not maintain secure and steady operation. Therefore, this paper analyzes the mechanism involved of the AC transient voltage during the AC fault and the recovery period first. It reveals that the key factor causing the TOV of the sending end system is the setting of the DC current reference value. Then, a DC current reference value limit method based on the AC TOV sampling value is proposed, which is used to accelerate DC current recovery and suppress the TOV of sending end system. Finally, based on the CIGRE Benchmark test model, the transient voltage analysis results and the validity of the designed control method are demonstrated by electromagnetic transient simulation.Keywords
This publication has 10 references indexed in Scilit:
- Concept and Definition of Dynamic Symmetrical Components With Time-Varying Amplitude and FrequencyIEEE Transactions on Energy Conversion, 2022
- Truncation Number Selection of Harmonic State-Space Model Based on the Floquet Characteristic ExponentIEEE Transactions on Industrial Electronics, 2022
- Overvoltage Suppression Under Commutation Failure Based on Improved Voltage-Dependent Current Order Limiter Control StrategyIEEE Transactions on Industry Applications, 2022
- Analysis of Transient Voltage Disturbances in LCC-HVDC Sending Systems Caused by Commutation FailuresIEEE Transactions on Power Delivery, 2022
- Reactive Power Control Strategy for Inhibiting Transient Overvoltage Caused by Commutation FailureIEEE Transactions on Power Systems, 2021
- Analytical Expression on Transient Overvoltage Peak Value of Converter Bus Caused by DC FaultsIEEE Transactions on Power Systems, 2021
- Research on CIGRE benchmark model and improved DC control strategyJournal of Physics: Conference Series, 2020
- Small-Signal Modeling and Analysis of MMC Under Unbalanced Grid Conditions Based on Linear Time-Periodic (LTP) MethodIEEE Transactions on Power Delivery, 2020
- Nonlinear Photovoltaic Controller Design to Suppress Overvoltage at the Sending End of HVDC Transmission Systems2019
- Emergency Control Strategy of PV for Suppressing Transient Overvoltage Peak in LCC-HVDC Infeed Power System2019