Effect of Restoration of Combined Offset on Stability of Large Head Tha
- 1 May 2012
- journal article
- research article
- Published by SAGE Publications in HIP International
- Vol. 22 (3) , 248-253
Abstract
Improvements in bearing technology have resulted in a reduction in wear and larger femoral heads to reduce dislocation rates. We retrospectively reviewed 668 primary THAs (580 patients) inserted with 32 mm or 36 mm femoral heads (1/2003–6/2007) performed through a posterior approach with posterior repair. Patients received a questionnaire assessing instability and dislocations. We compared clinical and radiographic data between patients with and without dislocations. Follow-up averaged 3.4 years (range 2–6.6 years). The dislocation rate was 1.3% (9/668). Decreasing the combined postoperative offset (lateral offset + medial offset measurements) and using acetabular cups larger than 58 mm in outer diameter increased the risk of dislocation. A majority of the hips that dislocated had negative combined offset and abduction angles in the upper and lower quartiles of all hips studied. Appropriate positioning should be used to minimise dislocation risk in THAs inserted with large femoral heads.Keywords
This publication has 22 references indexed in Scilit:
- Do Large Heads Enhance Stability and Restore Native Anatomy in Primary Total Hip Arthroplasty?Clinical Orthopaedics and Related Research, 2011
- Dislocation after total hip arthroplasty with 28 and 32-mm femoral headJournal of Orthopaedics and Traumatology, 2010
- Influence of Patient-, Design-, and Surgery-Related Factors on Rate of Dislocation After Primary Cementless Total Hip ArthroplastyThe Journal of Arthroplasty, 2009
- Reproducibility and Accuracy of Templating Uncemented THA With Digital Radiographic and Digital TraumaCad Templating SoftwareOrthopedics, 2009
- Outcome of treatment for dislocation after primary total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Instability After Total Hip ArthroplastyThe Journal of Arthroplasty, 2008
- Large Diameter Femoral Heads on Highly Cross-linked PolyethyleneClinical Orthopaedics and Related Research, 2006
- An Analysis of the Risk of Hip Dislocation with a Contemporary Total Joint RegistryClinical Orthopaedics and Related Research, 2006
- Reducing the risk of dislocation after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- THE OTTO AUFRANC AWARD: Highly Cross-linked Polyethylene in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004