Chemometric and learning-based multivariate models for quantifying a challenging quaternary mixture of bupropion, dextromethorphan, and their related impurities by UV-Vis spectrophotometry
Open Access
- 12 April 2026
- journal article
- research article
- Published by Springer Nature in BMC Chemistry
- Vol. 20 (1)
Abstract
This study presents a robust, green, sustainable and time-efficient approach for the simultaneous determination of Bupropion HCl (BUP) and Dextromethorphan HBr (DEX) along with their related impurities 3-Chlorobenzoic acid and N, N-Dimethylaniline. Principal component regression (PCR) and partial least-squares (PLS), in addition to advanced chemometric models, namely multivariate curve resolution-alternating least squares (MCR-ALS), and artificial neural networks (ANN), are the four green smart multivariate spectrophotometric models that were proposed and validated. The suggested models were successful in examining the mixture of BUP and DEX in the presence of their impurities. Therefore, the suggested analytical methods can be applied to pharmaceutical formulation analysis without the need for a separation step. The proposed strategy offers a novel analytical platform for quality control laboratories to manage complex formulations involving interfering substances. To further ensure greenness and sustainability of the proposed approach, several assessment tools were applied, including the Modified National Environmental Methods Index (NEMI), Eco-Scale, the Analytical GREEnness (AGREE) metric, the Hexagon algorithm, the Green Analytical Procedure Index (GAPI), the Modified GAPI (MoGAPI), the Blue Applicability Grade Index (BAGI), White Analytical Chemistry (WAC), and the Click Analytical Chemistry Index (CACI). Many traditional analytical techniques pose undesirable dangers to the environment and the analyst, such as using hazardous solvents. This gave analysts the incentive to use green methodologies that take into account the use of safe chemicals, the production of the least amount of trash, substantial time savings, and enhanced analyst safety.Keywords
Funding Information
- Cairo University
This publication has 47 references indexed in Scilit:
- Smartphone camera as a sustainable detector for intelligent HPTLC analysis of bupropion and dextromethorphan: A comparative study with standard densitometric imagingMicrochemical Journal, 2025
- Sustainable spectrophotometric determination of dextromethorphan and bupropion: A fourier self-deconvolution approachGreen Analytical Chemistry, 2025
- Advanced chemometric methods as powerful tools for impurity profiling of drug substances and drug products: Application on bisoprolol and perindopril binary mixtureSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2022
- A down-to-earth analyst view of rotational ambiguity in second-order calibration with multivariate curve resolution − a tutorialAnalytica Chimica Acta, 2021
- Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shapeAnalytica Chimica Acta, 2021
- Practical guidelines for reporting results in single- and multi-component analytical calibration: A tutorialAnalytica Chimica Acta, 2015
- MCR-ALS GUI 2.0: New features and applicationsChemometrics and Intelligent Laboratory Systems, 2015
- A new technique for spectrophotometric determination of Pseudoephedrine and Guaifenesin in syrup and synthetic mixtureDrug Testing and Analysis, 2011
- Batch process diagnosis: PLS with variable selection versus block-wise PCRChemometrics and Intelligent Laboratory Systems, 2004
- Multivariate detection limits estimatorsChemometrics and Intelligent Laboratory Systems, 1996