The arthroscopic treatment of displaced tibial spine fractures in children and adolescents using Meniscus Arrows®
Open Access
- 11 December 2010
- journal article
- knee
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (5) , 736-739
Abstract
Purpose: This article summarises the results of a newly developed technique that utilises Meniscus Arrows® for the arthroscopic fixation of displaced tibial spine fractures in children and adolescents.Method: Twelve tibial spine fractures in the knees of eleven children between 6 and 15 years old, with an average age of 12 years, were arthroscopically fixed with Meniscus Arrows®, after a reduction of their fractures. This was followed by 5 weeks immobilisation in a plaster of Paris. Postoperative follow‐up included radiographs, Lachmann tests on all of the children’s knees and KT‐1000 tests of eight out of twelve of the children’s knees. The postoperative follow‐up time ranged from 3 to 10 years, with patients being seen for an average of 4 years.Results: All of the fractures consolidated uneventfully, and all of the patients returned unrestricted to their previous activity level. The Lachmann tests revealed no, or a non‐functional, laxity in any of the patients’ knees. The KT‐1000 tests showed a difference between the operated side, and non‐operated side, of between 3 mm in the first knee operated on and an average of 1 mm in the remaining knees.Conclusion: The arthroscopic fixation of tibial spine fractures using Meniscus Arrows® showed that this minimally invasive procedure resulted in the uneventful consolidation of all twelve of the fractures, with excellent results, and without the need for a second, hardware removal, operation. Level of Evidence: Level IVKeywords
This publication has 25 references indexed in Scilit:
- Fixation of osteochondral fragments in the human knee using Meniscus Arrows®Knee Surgery, Sports Traumatology, Arthroscopy, 2010
- Arthroscopic Fixation of Anterior Tibial Spine Fractures with Bioabsorbable Nails in Skeletally Immature PatientsThe American Journal of Sports Medicine, 2009
- Clinical and radiological results of arthroscopically treated tibial spine fractures in childhoodInternational Orthopaedics, 2008
- Outcomes of Osteochondral Lesions of the Knee Repaired With a Bioabsorbable DeviceArthroscopy, 2007
- Comparison of Bioabsorbable Pins and Nails in the Fixation of Adult Osteochondritis Dissecans Fragments of the KneeThe American Journal of Sports Medicine, 2007
- Unsatisfactory Clinical Results of Meniscal Repair Using the Meniscus ArrowArthroscopy, 2005
- Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcomeArthroscopy, 2004
- Laxity and functional outcome after arthroscopic reduction and internal fixation of displaced tibial spine fractures in childrenArthroscopy, 2003
- Pediatric tibial eminence fractures: Arthroscopic cannulated screw fixationArthroscopy, 1995
- Tensile properties of the human femur-anterior cruciate ligament-tibia complexThe American Journal of Sports Medicine, 1991