Twenty‐four‐hour measurement of IOP in rabbits using rebound tonometer
Authors:
- 1 January 2013
- journal article
- research article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 16 (6) , 423-428
Abstract
Purpose To observe the Intraocular pressure (IOP) measurements over a 24-h period in New Zealand white rabbits. Methods Thirty-four normal New Zealand white rabbits (68 eyes) were included in this study. The IOP values were determined with a rebound tonometer (RBT, Icare VET). Measurements were always obtained in the right eye first. Results The data showed that there was no significant difference in IOP between measurements, which indicated that the RBT showed good repeatability in this study (P = 0.920). There was no statistically significant difference between genders (P = 0.943). The IOP in right eyes was a little higher than left eyes (F = 45.96, P < 0.001). Comparison of the true IOP and RBT results over the entire pressure range (8–100 mmHg) revealed a statistically significant difference between them (P < 0.001). The mean difference between the RBT and true IOP (RBT−True IOP) was −22.65 ± 9.52 mmHg with 95% confidence interval (−27.1, −18.2 mmHg). In the light period (7 AM to 7 PM), the IOP was a little lower than during the dark period (8 PM to 6 AM); 9 AM and 2 PM were the lowest measurements (10 mmHg, 9.625 mmHg), and 10 AM (14.125 mmHg)was the highest measurement during the 24-h period. Conclusions The IOP obtained by RBT underestimated the true IOP but the RBT had a good repeatability in IOP measurements. In the light period (7 AM to 7 PM), the IOP was a little lower than during the dark period (8 PM to 6 AM), which may be beneficial to the intervention therapy observation of glaucoma research in rabbits.Keywords
This publication has 24 references indexed in Scilit:
- Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogsVeterinary Ophthalmology, 2011
- Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplastyEye, 2011
- Suitability and calibration of a rebound tonometer to measure IOP in rabbit and pig eyesVeterinary Ophthalmology, 2011
- Accuracy and reproducibility of the TonoVet®rebound tonometer in birds of preyVeterinary Ophthalmology, 2010
- Is There a Relationship Between Blood Pressure and Intraocular Pressure? An Experimental Study in Hypertensive RatsCurrent Eye Research, 2008
- Evidence that a gender difference in intraocular pressure is present from childhoodOphthalmic and Physiological Optics, 2000
- Number of people with glaucoma worldwide.British Journal of Ophthalmology, 1996
- Intraocular pressure -physiology and implications for anaesthetic managementCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1986
- Circadian rhythm in intraocular pressure: A rabbit modelCurrent Eye Research, 1981
- INFLUENCE OF LIGHT ON THE 24‐HOUR VARIATION IN AQUEOUS FLARE DENSITY AND INTRA‐OCULAR PRESSURE IN NORMAL RABBITS' EYESActa Ophthalmologica, 1961