Abstract
Impedance mismatch that degrades signal power transfer and affects communication reliability is a major obstacle for power line communications (PLC). Impedance matching techniques can be designed to effectively compensate for the impedance mismatch between PLC modems and power line networks at a specific frequency or for a given frequency band. In this paper, we discuss the tradeoffs that need to be made when designing an effective impedance matching network. We also make a comprehensive review of previous state-of-the-art PLC impedance matching techniques and provide a useful classification of each technique. Finally, we discuss important issues (concerns) and provide suggestions for research directions deserving more attention. This review provides a useful guideline for researchers and manufacturers to quickly understand impedance matching principles and facilitate the design of an effective impedance matching coupler for PLC applications.
Funding Information
  • National Natural Science Foundation of China (61372044)
  • Natural Science Foundation of the Jiangsu Higher Education Institutions of China (14KJA510002)
  • Postgraduate Research & Practice Innovation Program of Jiangsu Province (KYCX18_0888)
  • Natural Science Foundation of Chuzhou University (zrjz2017008)

This publication has 107 references indexed in Scilit: