Instantaneous extracellular solution exchange for concurrent evaluation of membrane permeability of single cells
- 4 December 2023
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (2) , 281-291
Abstract
The osmotic stress imposed on microorganisms by hypotonic conditions is perceived to regulate water and solute flux via cell membranes, which are crucial for survival. Some cells that fail to perceive osmotic stress die because this results in the rupture of the cell membrane. The flux through the membrane is characterized by the membrane permeability, which is measured using a stopped-flow apparatus in response to a millisecond-order osmolarity change. However, the obtained data are an ensemble average of each cell response. Additionally, the measurement of permeability, considering cellular viability, contributes to a more accurate evaluation of osmoadaptation. Here, we present a novel on-chip instantaneous extracellular solution exchange method using an air–liquid interface. The presented method provides a concurrent evaluation at the single-cell level in response to a millisecond-order osmotic shock, considering cellular viability by solution exchange. This method utilizes a liquid bridge with a locally formed droplet on the surface of a micropillar fabricated inside a microchannel. We evaluated a solution exchange time of 3.6 ms and applied this method to Synechocystis PCC 6803 under two different osmolarity conditions. The live/dead ratio of 1 M to 0.5 M osmotic down shock condition was 78.8/21.2% while that of 1 M to 0.25 M osmotic down shock condition was 40.0/60.0%. We evaluated the water permeability of two groups: cells that were still live before and after osmotic shock (hereafter named cell type 1), and cells that were live before but were dead 10 minutes after osmotic shock (hereafter named cell type 2). The results indicated that the water permeability of cell type 2 was higher than that of cell type 1. The results obtained using the presented methods confirmed that the effect of osmotic stress can be accurately evaluated using single-cell analysis.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP21H04543, 22KJ0942)
- Ministry of Education, Culture, Sports, Science and Technology (JPMXP1222UT1033)
This publication has 33 references indexed in Scilit:
- Metabolic phenotyping of the cyanobacterium Synechocystis 6803 engineered for production of alkanes and free fatty acidsApplied Energy, 2013
- Aquaporin AqpZ Is Involved in Cell Volume Regulation and Sensitivity to Osmotic Stress in Synechocystis sp. Strain PCC 6803Journal of Bacteriology, 2012
- Characterization of three novel mechanosensitive channel activities inEscherichia coliChannels, 2012
- Integrated microfluidic bioprocessor for single-cell gene expression analysisProceedings of the National Academy of Sciences, 2008
- Mechanosensitive channels in bacteria: signs of closure?Nature Reviews Microbiology, 2007
- Hard and soft micromachining for BioMEMS: review of techniques and examples of applications in microfluidics and drug deliveryAdvanced Drug Delivery Reviews, 2004
- Salt Stress and Hyperosmotic Stress Regulate the Expression of Different Sets of Genes in Synechocystis sp. PCC 6803Biochemical and Biophysical Research Communications, 2002
- Experimental and theoretical scaling laws for transverse diffusive broadening in two-phase laminar flows in microchannelsApplied Physics Letters, 2000
- Sequence Analysis of the Genome of the Unicellular Cyanobacterium Synechocystis sp. Strain PCC6803. II. Sequence Determination of the Entire Genome and Assignment of Potential Protein-coding RegionsDNA Research, 1996
- Stopped-flow apparatus for the study of rapid reactionsDiscussions of the Faraday Society, 1954