Hand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography
Open Access
- 17 November 2004
- journal article
- research article
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 2 (1) , 24
Abstract
Background: Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE), in cardiology inpatient setting. Methods: We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men) who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training) and considered as the gold standard. Results: There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58). There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85), aortic regurgitation (kappa = 0.89), and tricuspid regurgitation (Kappa = 0.74). A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion: Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.Keywords
This publication has 13 references indexed in Scilit:
- Utility and diagnostic accuracy of hand-carried ultrasound for emergency room evaluation of chest painThe American Journal of Cardiology, 2004
- Hand-held echocardiography with doppler capability for the assessment of critically-ill patients: is it reliable?Intensive Care Medicine, 2004
- Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and doppler echocardiographyJournal of the American Society of Echocardiography, 2003
- ACC/AHA clinical competence statement on echocardiography11When citing this document, the American College of Cardiology, the American Heart Association, and the American College of Physicians–American Society of Internal Medicine would appreciate the following citation format: Quiñones MA, Douglas PS, Foster E, Gorcsan J, Lewis JF, Pearlman AS, Rychik J, Salcedo EE, Seward J, Stevenson JG, Thys DM, Weitz HH, and Zoghbi WA. ACC/AHA clinical competence statement on echocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians–American Society of Internal Medicine Task Force on Clinical Competence (Committee on Echocardiography). J Am Coll Cardiol 2003;41:687–708.22This document was approved by the American College of Cardiology Board of Trustees in December 2002 and the American Heart Association Science Advisory and Coordinating Committee in November 2002.**Address for Reprints: This document is available on the Web sites of the American College of Cardiology (www.acc.org), the American Heart Association (www.americanheart.org), the American Society of Echocardiography (http://asecho.org), and the Society of Pediatric Echocardiography (www.sopeonline.com). Reprints of this document may be purchased for $5.00 each by calling 1-800-253-4636 or by writing to the American College of Cardiology, Resource Center, 9111 Old Georgetown Road, Bethesda, Maryland 20814-1699.JACC, 2003
- Usefulness of a hand-held ultrasound device for bedside examination of left ventricular functionThe American Journal of Cardiology, 2002
- Left ventricular hypertrophy screening using a hand-held ultrasound deviceEuropean Heart Journal, 2002
- How useful is hand-carried bedside echocardiography in critically ill patients?JACC, 2001
- Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image qualityThe American Journal of Cardiology, 1998
- Recommendations for Quantitation of the Left Ventricle by Two-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 1989
- Transesophageal EchocardiographyJournal of the American Society of Echocardiography, 1989