Robust and Adaptive Tuning of PI Current Controllers for Grid-Forming Inverters
Open Access
- 30 December 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 6, 115-129
Abstract
In recent years, GFM inverters have become an increasingly active research interest, due to their ability to form autonomous grids and to maintain synchronism also in purely power electronics based environments. The main building blocks of these machines are several PWM controlled switches, receiving energy from the DC side, followed by $LC$ or $LCL$ output filters to produce nearly sinusoidal currents injected into the power grid. The filter inductances are usually small, to avoid high costs, such that tiny voltage measurement-, delay- or PWM timing-errors can cause large deviations in the output currents. This is mitigated by employing fast OCC which allow to correct the effect of measurement errors and delays and accurately track the reference currents. These controllers can be implemented as PI controllers in a rotating reference frame or PR controllers or even more complex structures. GFM inverters usually employ virtual impedances to obtain the reference currents for the OCC. While very efficient in strong grids, such control architectures face stability problems if the grid SCR becomes low. While for GFL inverters, this problem has been well researched in the past years, and various solutions have been proposed, for GFM inverters, the adequate tuning of the virtual impedances and the current controller parameters has yet to be fully understood. In this paper we investigate the influence of the grid impedance, and various control parameters of a GFM inverter with PI current controllers and virtual impedances, and give recommendations for the tuning of all the conditions. We further suggest an updated procedure to select $LCL$ filter values and demonstrate the suggested tuning in an experimental setup. To enable automatic tuning online, we employ a method for measuring the grid impedance by injecting a small probing current into the grid, at a frequency that is close but different from the grid frequency.Keywords
All Related Versions
Funding Information
- Israel Science Foundation (2802/21)
This publication has 33 references indexed in Scilit:
- Grid impedance measurement for inverters with current controllers and virtual impedances2024
- Virtual Friction Subjected to Communication Delays in a Microgrid of Virtual Synchronous MachinesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2023
- A comprehensive comparison of Virtual Synchronous Generators with focus on virtual inertia and frequency regulationElectric Power Systems Research, 2021
- The Sensitivity of Grid-Connected Synchronverters With Respect to Measurement ErrorsIEEE Access, 2021
- Grid Forming Inverter Modeling, Control, and ApplicationsIEEE Access, 2021
- Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A ReviewIEEE Open Journal of Industry Applications, 2021
- Notch-Filter Active Damping of LCL Filter Resonance in a Grid-connected Inverter with Variable Grid Inductance2019
- Almost global asymptotic stability of a grid-connected synchronous generatorMathematics of Control, Signals, and Systems, 2018
- System strength considerations in a converter dominated power systemIET Renewable Power Generation, 2015
- Padé Approximants Second Edition1996