PET/CT-guided biopsy with respiratory motion correction
Authors:
- 11 September 2019
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (12) , 2187-2198
Abstract
Purpose Given the ability of positron emission tomography (PET) imaging to localize malignancies in heterogeneous tumors and tumors that lack an X-ray computed tomography (CT) correlate, combined PET/CT-guided biopsy may improve the diagnostic yield of biopsies. However, PET and CT images are naturally susceptible to problems due to respiratory motion, leading to imprecise tumor localization and shape distortion. To facilitate PET/CT-guided needle biopsy, we developed and investigated the feasibility of a workflow that allows to bring PET image guidance into interventional CT suite while accounting for respiratory motion. Methods The performance of PET/CT respiratory motion correction using registered and summed phases method was evaluated through computer simulations using the mathematical 4D extended cardiac-torso phantom, with motion simulated from real respiratory traces. The performance of PET/CT-guided biopsy procedure was evaluated through operation on a physical anthropomorphic phantom. Vials containing radiolabeled 18F-fluorodeoxyglucose were placed within the physical phantom thorax as biopsy targets. We measured the average distance between target center and the simulated biopsy location among multiple trials to evaluate the biopsy localization accuracy. Results The computer simulation results showed that the RASP method generated PET images with a significantly reduced noise of 0.10 ± 0.01 standardized uptake value (SUV) as compared to an end-of-expiration image noise of 0.34 ± 0.04 SUV. The respiratory motion increased the apparent liver lesion size from 5.4 ± 1.1 to 35.3 ± 3.0 cc. The RASP algorithm reduced this to 15.7 ± 3.7 cc. The distances between the centroids for the static image lesion and two moving lesions in the liver and lung, when reconstructed with the RASP algorithm, were 0.83 ± 0.72 mm and 0.42 ± 0.72 mm. For the ungated imaging, these values increased to 3.48 ± 1.45 mm and 2.5 ± 0.12 mm, respectively. For the ungated imaging, this increased to 1.99 ± 1.72 mm. In addition, the lesion activity estimation (e.g., SUV) was accurate and constant for images reconstructed using the RASP algorithm, whereas large activity bias and variations (± 50%) were observed for lesions in the ungated images. The physical phantom studies demonstrated a biopsy needle localization error of 2.9 ± 0.9 mm from CT. Combined with the localization errors due to respiration for the PET images from simulations, the overall estimated lesion localization error would be 3.08 mm for PET-guided biopsies images using RASP and 3.64 mm when using ungated PET images. In other words, RASP reduced the localization error by approximately 0.6 mm. The combined error analysis showed that replacing the standard end-of-expiration images with the proposed RASP method in PET/CT-guided biopsy workflow yields comparable lesion localization accuracy and reduced image noise. Conclusion The RASP method can produce PET images with reduced noise, attenuation artifacts and respiratory motion, resulting in more accurate lesion localization. Testing the PET/CT-guided biopsy workflow using computer simulation and physical phantoms with respiratory motion, we demonstrated that guided biopsy procedure with the RASP method can benefit from improved PET image quality due to noise reduction, without compromising the accuracy of lesion localization.Keywords
Funding Information
- National Institutes of Health (R01 CA160253, R42 CA153488, R42 CA167907)
This publication has 30 references indexed in Scilit:
- Real-time FDG PET Guidance during Biopsies and Radiofrequency Ablation Using Multimodality Fusion with Electromagnetic NavigationRadiology, 2011
- The impact of respiratory motion on tumor quantification and delineation in static PET/CT imagingPhysics in Medicine & Biology, 2009
- PET/CT-Guided Percutaneous Biopsy of Isolated Intramuscular Metastases from Postcricoid CancerJournal of Nuclear Medicine Technology, 2009
- PET/CT guidance for percutaneous fine needle aspiration cytology/biopsyIndian Journal of Radiology and Imaging, 2009
- Electromagnetic tracking in the clinical environmentMedical Physics, 2009
- Designing tracking software for image-guided surgery applications: IGSTK experienceInternational Journal of Computer Assisted Radiology and Surgery, 2008
- Positron Emission Tomography–CT Imaging in Guiding Musculoskeletal BiopsyRadiologic Clinics of North America, 2008
- The accuracy of integrated PET-CT compared with dedicated pet alone for the staging of patients with nonsmall cell lung cancerThe Annals of Thoracic Surgery, 2004
- Staging of Non–Small-Cell Lung Cancer with Integrated Positron-Emission Tomography and Computed TomographyNew England Journal of Medicine, 2003
- 18-Fluorodeoxyglucose positron emission tomographic imaging in the detection and monitoring of infection and inflammationSeminars in Nuclear Medicine, 2002