Electrical conductivity images of biological tissue phantoms in MREIT
Authors:
- Byung Il LeeBLByung Il Lee
- Eung Je WooEWEung Je Woo
- Soo Yeol LeeSLSoo Yeol Lee
- Tae-Seong KimTKTae-Seong Kim
- Ohin KwonOKOhin Kwon
- Jin Keun SeoJSJin Keun Seo
- 30 March 2005
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 26 (2) , S279-S288
Abstract
We present cross-sectional conductivity images of two biological tissue phantoms. Each of the cylindrical phantoms with both diameter and height of 140 mm contained chunks of biological tissues such as bovine tongue and liver, porcine muscle and chicken breast within a conductive agar gelatin as the background medium. We attached four recessed electrodes on the sides of the phantom with equal spacing among them. Injecting current pulses of 480 or 120 mA ms into the phantom along two different directions, we measured the z-component Bz of the induced magnetic flux density B=(Bx, By, Bz) with a magnetic resonance electrical impedance tomography (MREIT) system based on a 3.0 T MRI scanner. Using the harmonic Bz algorithm, we reconstructed cross-sectional conductivity images from the measured Bz data. Reconstructed images clearly distinguish different tissues in terms of both their shapes and conductivity values. In this paper, we experimentally demonstrate the feasibility of the MREIT technique in producing conductivity images of different biological soft tissues with a high spatial resolution and accuracy when we use a sufficient amount of the injection current.Keywords
This publication has 21 references indexed in Scilit:
- Magnetic resonance electrical impedance tomography at 3 tesla field strengthMagnetic Resonance in Medicine, 2004
- Algebraic reconstruction for 3D magnetic resonance–electrical impedance tomography (MREIT) using one component of magnetic flux densityPhysiological Measurement, 2004
- Conductivity and current density image reconstruction using harmonicBzalgorithm in magnetic resonance electrical impedance tomographyPhysics in Medicine & Biology, 2003
- Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodesPhysics in Medicine & Biology, 2003
- Uniqueness and reconstruction in magnetic resonance electrical impedance tomography (MR EIT)Physiological Measurement, 2003
- Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT)Physiological Measurement, 2003
- J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity imagesIEEE Transactions on Medical Imaging, 2002
- Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithmIEEE Transactions on Biomedical Engineering, 2002
- Functional MRI with simultaneous EEG recording: Feasibility and application to motor and visual activationJournal of Magnetic Resonance Imaging, 2001
- Imaging with electricity: Report of the European Concerted Action on Impedance TomographyJournal of Medical Engineering & Technology, 1997